Emerson HF1160BQ02 Owner's Manual page 15

60” industrial fan
Table of Contents

Advertisement

Available languages

Available languages

BP7272-4 HF1160.qxp_BP7272 9/10/15 9:44 PM Page 15
6.7
Connect the Wall Control BLACK wire to the 120 VAC
source hot BLACK wire using a new wire connector
(supplied) (Figure 25).
6.8
Securely connect the GREEN ground wire from the Wall
Control to the supply ground wire (bare or green)
(Figure 26).
Check to see that all wire connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for ground.
6.9
NOTE: The WHITE neutral wires inside the electrical
box must be connected together for proper operation
of the wall control. NEVER connect the WHITE neutral
wires to the Wall Control (Figure 27).
Do not connect any neutral (WHITE) wire to this control.
Incorrect wiring WILL damage this control.
6. Wall Control Installation
WARNING
!
WARNING
!
(Continued)
WIRE CONNECTOR
WALL CONTROL
BLACK WIRE
120 VAC HOT
BLACK WIRE
WALL
CONTROL
Figure 25
WALL CONTROL
GREEN GROUND
WIRE
CONNECTOR
Figure 26
DO NOT CONNECT ANY WIRES FROM
WALL CONTROL TO THESE WHITE
NEUTRAL WIRES
Figure 27
Please contact 1-800-654-3545 for further assistance
15
TO FAN
MOTOR LOAD
TO 120VAC
SOURCE HOT
SUPPLY GREEN
GROUND WIRE
WIRE
TO FAN
MOTOR LOAD
TO 120VAC
SOURCE HOT
emersonfans.com
U.L. Model No.: HF1160-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hf1160bs02Hf1160ww02

Table of Contents