Download Print this page

Daikin ARKC18RV2S Service Manual page 7

Outdoor unit 4.2/5.0/6.0 kw class 18000/24000 btu/h class

Advertisement

Si001413EB
Step
4
Remove the nut and
remove the outdoor fan.
5
Remove the 2 screws
of the fan motor fixing
frame.
6
Pull up the fan motor
fixing frame to unfasten
the 2 hooks at the
bottom.
7
Remove the fan motor
fixing frame.
8
Unfasten the 2 hooks
and release the fan
motor lead wire.
9
Remove the 4 screws
and remove the fan
motor.
Removal Procedure
Procedure
Nut
Outdoor fan
Fan motor
fixing frame
Hook
(R20312)
(R20668)
(R22019)
Fan motor
(R20316)
Outdoor Fan / Fan Motor
Points
Nut size: M6
10 mm
(0.39 inch)
(R18954)
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
When reassembling, fit the 2
lower hooks into the bottom
frame.
(R20314)
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
Lead wire
Outdoor fan
(R3249)
5