Step
2
Pull out the compressor
lead wires.
3
Pull out the overload
protector.
4
Remove the protection
bushing.
5
Remove the putty.
6
Heat up the brazed part
of the discharge side
and disconnect it.
7
Heat up the brazed part
of the suction side and
disconnect it.
8
Remove the 2 nuts.
9
Lift up the compressor
and remove it.
Removal Procedure
Procedure
V (yellow)
W (blue)
U (red)
Protection bushing
Nut
This is the view from the
back side.
Overload protector
(R23353)
Brazed part
Putty
Compressor
(R23399)
Compressor
Points