Si041255EH
Step
5
Slightly pull out the
auxiliary piping.
6
Unfasten the 2 hooks
on the left side.
7
Push the 2 hooks on
the right side and
unfasten them.
8
Pull the indoor heat
exchanger to the front
side and unfasten the
hooks completely, and
then lift the indoor heat
exchanger.
Removal Procedure
Procedure
Hook
Indoor heat exchanger
Auxiliary piping
(R11367)
Hook
(R17680)
(R13517)
(R17681)
Indoor Heat Exchanger
Points
15