PCBs
Step
4
Disconnect the
connector [S49] from
the display PCB.
5
Unfasten the 4 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
6
Disconnect the
connector [S36].
7
Unfasten the 2 hooks
and remove the signal
receiver PCB.
8
Disconnect the
connector [S48].
10
Procedure
[S49]
INTELLIGENT EYE
sensor PCB
[S36]
Signal receiver
PCB
[S48]
Points
[S49]: control PCB
(R11352)
Some models have no
INTELLIGENT EYE sensor
PCB.
[S36]: control PCB
(R11353)
[S48]: control PCB
(R11354)