Function Tests Setup
1 Position the machine on a firm surface directly
below the desired work area.
2 Connect to the appropriate power source: DC
models: Connect the battery pack. AC models:
Connect to a grounded 15A AC power supply.
Use a 12 gauge / 3.3mm
extension cord no longer than 50 feet / 13 m.
© Result: The power light should come on.
3 Turn on the circuit breaker.
4 Insert the key and turn to ground control or
platform control.
5 Twist the red Emergency Stop buttons to the on
position both at the ground and the platform
controls.
6 Take an outrigger and slide it into a base socket
until the outrigger lock pin snaps into place. Adjust
the outrigger to level the machine and raise the base
casters slightly off the ground. Level the machine
using only the outriggers.
7 Check the interlock display lights at the ground
controls. Confirm that the corresponding light is on.
8 Repeat this procedure for each of the remaining
outriggers.
9 Use the bubble level and adjust the leveling jacks
until the machine base is level.
3-wire grounded
2
10 Push in the up/down switch at ground
control in the direction of intended travel. (Turn
the key switch to ground control)
© Result: The up/down function should not
operate
11 Push in the control activate button and rotate
the up/down switch at the platform in the
direction of intended travel. (Turn the key switch
to platform control)
© Result: The up/down function should not
operate.
12 Push in the red Emergency Stop button at
the platform controls to the off position.
13 Twist the red Emergency Stop button at the
ground controls to the on position.
14 Push in the up/down switch at ground
control in the direction of intended travel. (Turn
the key switch to ground control)
© Result: The up/down function should not
operate
15 Push in the control activate button and rotate
the up/down switch at the platform in the
direction of intended travel. (Turn the key switch
to platform control).
© Result: The up/down function should not
operate