Z-Wave Plus Info
Role Type
Node Type
Slave Sleeping
Z-Wave Plus node
Listening
Association Command Class
Group
1
Version
Protocol Library
3 (Slave_Enhance_232_Library)
Protocol Version
6.04(6.81.03)
Manufacturer
Manufacturer ID
Product Type
0x0060
0x0015
AGI (Association Group Information) Table
Group
Profile
Command Class & Command (List) N bytes
Battery Report,
Device Reset Locally Notification,
Notification Report
Sensor Multilevel Report
1
General
Thermostat Mode Report
Thermostat Setpoint Report
Protection Report
Clock Report
Notification
Event
The power is applied for the first time
Battery
Battery Report (value)
Description
20~100
Battery Level %
0xFF
Low Battery
Command Classes
The module supports Command Classes including...
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Installer Icon
User Icon
Generic_Thermostat
Generic_Thermostat
Max Node
1
Product ID
0x0001
Group Name(UTF-8)
Lifeline
Event
Event
Type
Event
Parameter
Parameter
Length
0x08
0x01
0x00
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_APPLICATION_STATUS
COMMAND_CLASS_THERMOSTAT_MODE_V3
COMMAND_CLASS_THERMOSTAT_SETPOINT_V3
COMMAND_CLASS_PROTECTION
COMMAND_CLASS_CLOCK
Basic Command Class
Basic Get: Command to inquire the status of the device.
Basic Report: Report the status of the device.
Basic Set: Set the status of the device.
Basic Set Value
Description
0x00
Energy Heat
0x0F
Off
0xFF
Heat
Z-Wave Configuration
1.
Temperature Auto Report period setting
Parameter Number
Size
1
2
2.
Temperature offset for internal sensor
Parameter Number
Size
2
1
3.
Maximum Set point value
Parameter Number
Size
3
1
4.
Minimum Set point value
Parameter Number
Size
4
1
5.
Frost protection temperature
Parameter Number
Size
5
1
6.
Open window detect function
Parameter Number
Size
6
1
7.
Open window detect time period
Parameter Number
Size
7
1
8.
Open window detect temperature drop setting
Parameter Number
Size
8
1
9.
Open window detect delay time select
Parameter Number
Size
9
1
Range
Default
1~255 (min)
120mins
Range
Default
-80~+80 Offsets the
℃
measured temperature by
00=0.0
℃
℃
-8.0
~+8.0
Range
Default
℃
℃
5~35 for 5
~35
35=35
Range
Default
℃
℃
5~35 for 5
~35
5=5
Range
Default
℃
℃
5~15 for 5
~15
5=5℃
Range
Default
0: Disable
1: Enable
Range
Default
2~30 (min)
15mins
Range
Default
℃
℃
4=2
, 5=2.5
℃
℃
℃
4=2
6= 3
, 7=3.5
, 8=4
Range
Default
10~60 (min)
30mins
Offset
℃
℃
0
℃
Need help?