EVERSPRING AD142 Manual

Lamp module

Advertisement

Quick Links

AD142
LAMP MODULE
This plug-in Lamp Module is a transceiver which is a Z-Wave
is fully compatible with any Z-Wave
TM
displaying the Z-Wave
logo can also be used with it regardless of the manufacturer,
and ours can also be used in other manufacturer's Z-Wave
Inclusion of the Lamp Module on other manufacturer's Wireless Controller menu
allows remote On/Off control and dimming of lamps connected. Each module is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure
that the signal is received by its intended destination by routing the signal around
obstacles and radio dead spots. The plug-in Lamp Module is compatible with our
Motion Detectors SP103 and Door/Window Detectors SM103.
TM
Adding to Z-Wave
Network
In the front casing, there is an On/Off/Dim knob which is used to carry out inclusion,
exclusion or association. Put a Z-Wave
mode, press the knob on the Module to complete the inclusion/exclusion process.
On/Off/Dim Knob
LED Indicator
Installation
1. Plug this Lamp Module into a wall outlet near the lamp to be controlled.
2. Plug the lamp into the Lamp Module. Make sure the lamp to be controlled
cannot exceed 400 watts.
3. Turn the knob or switch on the lamp to the ON position.
4. To manually turn ON the Lamp Module, press and release the On/Off/Dim knob.
The red indicator LED will turn ON, and the lamp plugged into the Lamp Module
will also turn ON.
TM
enabled device and
TM
TM
enabled network. Z-Wave
enabled devices
TM
enabled networks.
TM
Wireless Controller into inclusion/exclusion
5. To manually turn OFF the Lamp Module, simply press and release the
On/Off/Dim knob. The red indicator LED will turn OFF and the lamp plugged into
the Module will also turn OFF.
6. To manually dim the Lamp Module, press and hold the On/Off/Dim knob until the
desired lighting level has been reached.
7. If Motion Detector SP103 or Door/Window Detector SM103 has been removed
from the wall by triggering the tamper switch, the Detector (SP103 or SM103) will
send an alarm command (ALARM_REPORT, Alarm Type == 0x01, Alarm Level
== 0x11) to the Module, of which red indicator LED and the lamp plugged into the
Module will flash for 10 times simultaneously.
Programming
The On/Off/Dim knob allows the user
-
Turn on, off or dim the lamp attached
-
Include or exclude the Module from the Z-Wave
TM
-
Control other Z-Wave
enabled devices
See the instructions for SP103 Motion Detector or SM103 Door/Window Detector.
Troubleshooting
Symptom
The Module not working and
LED off
The Module LED illuminating,
but cannot control the ON/OFF
Switch of the lamp attached
The Module LED illuminating,
but the Detector cannot control
the Module
1
TM
system
Cause of Failure
Recommendation
1. The Module is not
1. Check power connections
plugged into the
2. Don't open up the Module and
electrical outlet
send it for repair.
properly
2. The Module is out of
order
Check if the lamp plugged
Replace a new lamp
into the Module has
burned out
1. Not carry out
1. Carry out association
association
2. Wait for a while to re-try
2. Frequency interference

Advertisement

loading

Summary of Contents for EVERSPRING AD142

  • Page 1 5. To manually turn OFF the Lamp Module, simply press and release the AD142 LAMP MODULE On/Off/Dim knob. The red indicator LED will turn OFF and the lamp plugged into the Module will also turn OFF. This plug-in Lamp Module is a transceiver which is a Z-Wave enabled device and 6.
  • Page 2 Maximum Load 400W, for incandescent lamps only socket suited for each country as follows: Minimum Load 25W, for incandescent lamps only Range Minimum 30 m line of sight AD142-2 Germany AD142-3 U.K. Frequency Range 868.42 MHz A501111352R ** Specifications are subject to change and improvement without notice.