AN128
ON/OFF MODULE
This plug-in On/Off Module is a transceiver which is a Z-Wave
and is fully compatible with any Z-Wave
TM
devices displaying the Z-Wave
logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer's Z-Wave
enabled networks. Remote On/Off control of the connected load is possible with
other manufacturer's Wireless Controller. Each module is designed to act as a
repeater. Repeaters will re-transmit the RF signal to ensure that the signal is
received by its intended destination by routing the signal around obstacles and
radio dead spots.
TM
Adding to Z-Wave
Network
In the front casing, there is an On/Off knob which is used to carry out inclusion,
exclusion
or
association.
Put
inclusion/exclusion mode, press the On/Off knob on the module to complete the
inclusion/exclusion process.
Function
Description
Inclusion
1.
Put the Z-Wave Controller into inclusion mode.
2.
Press the On/Off/Dim knob once to enter inclusion mode.
Exclusion
1.
Put the Z-Wave Controller into exclusion mode.
2.
Press the On/Off/Dim knob once to enter exclusion mode.
3.
Node ID has been excluded.
Association
1.
Operate the Z-Wave Controller to start association process.
2. Press the On/Off/Dim knob once to execute association.
TM
enabled device
TM
TM
enabled network. Z-Wave
TM
a
Z-Wave
Wireless
Controller
Controllable outlet
Pass-through outlet
On /Off knob
Installation
1. Plug this On/Off Module into a wall outlet near the load to be controlled.
2. Plug the appliances into the On/Off Module. There are two outlets at different
sides of AN128. The appliances plugged into the controllable outlet can be
controlled by the On/Off knob and remote controller, the other side is
non-controlled and acts as a pass-through outlet. Make sure the total load of
enabled
both sides cannot exceed 1500 watts which means if the load of controllable
outlet is changed, the other side will be altered accordingly. For instance, if the
TM
load of controllable outlet is about 1500 watts, the other should be 0 watt; while
if the load of controllable outlet is 1200 watts, the other should be 300 watts.
3. Turn the knob or switch on the load to the ON position.
4. To manually turn ON the AN128 On/Off Module, press and release the On/Off
knob. The red indicator LED will turn ON, and the load plugged into the AN128
On/Off Module will also turn ON.
5. To manually turn OFF the AN128 On/Off Module, simply press and release the
On/Off knob. The red indicator LED will turn OFF and the load plugged into the
into
AN128 On/Off Module will also turn OFF.
Programming
The On/Off knob allows the user
-
Turn on or off the load attached
-
Include or exclude the module from the Z-Wave
-
Control other Z-Wave
Advanced Operation:
As long as any Z-Wave
command
(ALARM_REPORT, Alarm Type == 0x01, Alarm Level == 0x11)
to the AN128 ON/OFF Module will enable its red indicator LED and the load
plugged into the AN128 ON/OFF Module to be on and off intermittently for 10
seconds.
Troubleshooting
Symptom
The Module not working and
LED off
The Module LED illuminating,
but cannot control the ON/OFF
Switch of the load attached
The Module LED illuminating,
but the Detector cannot control
the Module
TM
system
TM
enabled devices
TM
enabled device that can send below mentioned alarm
Cause of Failure
Recommendation
1. The Module is not
1. Check power connections
plugged into the
2. Don't open up the Module and
electrical outlet
send it for repair.
properly
2. The Module break
down
Check if the load plugged
Set the ON/OFF switch of the
into the Module has its
load attached to ON
own ON/OFF switch
1. Not carry out
1. Carry out association
association
2. Wait for a while to re-try
2. Frequency interference
Need help?
Do you have a question about the AN128 and is the answer not in the manual?
Questions and answers