AN158
ON/OFF MODULE
This plug-in ON/OFF Module is a transceiver which is a Z-Wave
and is fully compatible with any Z-Wave
TM
devices displaying the Z-Wave
manufacturer, and ours can also be used in other manufacturer's Z-Wave
networks. Remote On/Off control of the connected load is possible with other
manufacturer's Wireless Controller. Each module is designed to act as a repeater.
Repeaters will re-transmit the RF signal to ensure that the signal is received by its
intended destination by routing the signal around obstacles and radio dead spots.
The plug-in ON/OFF Module is compatible with our Motion Detectors SP814 and
Door/Window Detectors SM103.
This plug-in ON/OFF Module is able to detect current wattage (5~3150W) and
overload wattage (3010~3300W) of connected non-dimmable lights or appliances.
When detecting overload state, the Module will be disabled and its On/Off button will
be locked out of which LED will flash quickly for 30 seconds. However, unplug and
re-connect the Module will reset its overload condition to normal status.
Include to or Exclude from a Z-Wave
In the front casing, there is an On/Off button with LED indicator which is used to carry
out inclusion, exclusion, reset or association. Toggle On/Off button between On and
Off. When first power is applied, its LED flashes on and off alternately and repeatedly
at 2-second intervals. It implies that it has not been assigned a node ID and cannot
work with Z-Wave enabled devices. Please get familiar with the terms below before
starting the operations.
On/Off Button
LED Indicator
Function
Inclusion
Add a Z-Wave enabled device (e.g. On/Off Module) to Z-Wave network.
Exclusion
Delete a Z-Wave enabled device (e.g. On/Off Module) from the network.
TM
TM
enabled network. Z-Wave
logo can also be used with it regardless of the
TM
Network
Description
Function
Association
enabled device
Reset
TM
enabled
The table below lists an operation summary of basic Z-Wave functions. Please refer
TM
enabled
to the instructions for your Z-Wave
setup function, and to include/exclude/associate devices.
Function
No node ID
Inclusion
Exclusion
Reset
Association
1
Description
After inclusion, you have to define the relationship between devices.
Through association, device can be assigned as master/slave, and specify
which slave is going to be controlled by which master.
Restore On/Off Module to factory default.
TM
Certificated Primary Controller to access the
Description
The Z-Wave Controller does not allocate
a node ID to the Module.
1.
Have Z-Wave Controller entered
inclusion mode.
2. Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode.
1.
Have Z-Wave Controller entered
exclusion mode.
2.
Pressing On/Off button three times
within 1.5 seconds will enter
exclusion mode.
Node ID has been excluded.
1.
Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode.
2.
Within 1 second, press On/Off
button again for 5 seconds until LED
is off.
3.
IDs are excluded.
1.
Have Z-Wave Controller entered
association mode.
Or Pressing On/Off button three times
within 1.5 seconds will enter
association mode
2. There are two groupings - 1 and 2.
Refer to Z-Wave's Groups as
described on page 3 & 4.
LED Indication
2-second on, 2-second off
Press On, for on
Press Off, for off
Press On, for on
Press Off, for off
2-second on, 2-second off
Press On, for on
Press Off, for off
2-second on, 2-second off
Press On, for on
Press Off, for off