ON/OFF MODULE
This plug-in ON/OFF Module is a transceiver which is a Z-Wave
and is fully compatible with any Z-Wave
TM
devices displaying the Z-Wave
manufacturer, and ours can also be used in other manufacturer's Z-Wave
networks. Remote On/Off control of the connected load is possible with other
manufacturer's Wireless Controller. Each module is designed to act as a repeater.
Repeaters will re-transmit the RF signal to ensure that the signal is received by its
intended destination by routing the signal around obstacles and radio dead spots.
The plug-in ON/OFF Module is compatible with our Motion Detectors SP814 and
Door/Window Detectors SM103.
This plug-in ON/OFF Module is able to detect current wattage (5~3150W) and
overload wattage (3010~3300W) of connected non-dimmable lights or appliances.
When detecting overload state, the Module will be disabled and its On/Off button will
be locked out of which LED will flash quickly for 30 seconds. However, unplug and
re-connect the Module will reset its overload condition to normal status.
Include to or Exclude from a Z-Wave
In the front casing, there is an On/Off button with LED indicator which is used to carry
out inclusion, exclusion, reset or association. Toggle On/Off button between On and
Off. When first power is applied, its LED flashes on and off alternately and repeatedly
at 2-second intervals. It implies that it has not been assigned a node ID and cannot
work with Z-Wave enabled devices. Please get familiar with the terms below before
starting the operations.
On/Off Button
LED Indicator
Function
Inclusion
Add a Z-Wave enabled device (e.g. On/Off Module) to Z-Wave network.
Exclusion
Delete a Z-Wave enabled device (e.g. On/Off Module) from the network.
TM
TM
enabled network. Z-Wave
logo can also be used with it regardless of the
TM
Network
Description
Function
Association
enabled device
Reset
TM
enabled
The table below lists an operation summary of basic Z-Wave functions. Please refer
TM
enabled
to the instructions for your Z-Wave
setup function, and to include/exclude/associate devices.
Function
No node ID
Inclusion
Exclusion
Reset
Association
1
Description
After inclusion, you have to define the relationship between devices.
Through association, device can be assigned as master/slave, and specify
which slave is going to be controlled by which master.
Restore On/Off Module to factory default.
TM
Certificated Primary Controller to access the
Description
The Z-Wave Controller does not allocate
a node ID to the Module.
1.
Have Z-Wave Controller entered
inclusion mode.
2. Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode.
1.
Have Z-Wave Controller entered
exclusion mode.
2.
Pressing On/Off button three times
within 1.5 seconds will enter
exclusion mode.
Node ID has been excluded.
1.
Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode.
2.
Within 1 second, press On/Off
button again for 5 seconds until LED
is off.
3.
IDs are excluded.
1.
Have Z-Wave Controller entered
association mode.
Or Pressing On/Off button three times
within 1.5 seconds will enter
association mode
2. There are two groupings - 1 and 2.
Refer to Z-Wave's Groups as
described on page 3 & 4.
LED Indication
2-second on, 2-second off
Press On, for on
Press Off, for off
Press On, for on
Press Off, for off
2-second on, 2-second off
Press On, for on
Press Off, for off
2-second on, 2-second off
Press On, for on
Press Off, for off

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AN158 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EVERSPRING AN158

  • Page 1 Function Description AN158 ON/OFF MODULE Association After inclusion, you have to define the relationship between devices. Through association, device can be assigned as master/slave, and specify which slave is going to be controlled by which master. This plug-in ON/OFF Module is a transceiver which is a Z-Wave...
  • Page 2: Led Indication

    4. To manually turn ON the Module, press and release the On/Off button. The LED Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node will turn ON, and the load plugged into the Module will also turn ON. ID allocated by Z-Wave Controller means exclusion.
  • Page 3 “send basic command to grouping 2”. 2-1 Grouping 1 (Maximum Node 1) Note: AN158 can associate up to 4 pc of AN158, acting as an active and passive 2-1-1 POWER_APPLIED command device respectively. The active one cannot be set and controlled by passive The Module will send ALARM_REPORT command to the nodes of Grouping 1 to device.
  • Page 4 the node of Grouping 1. 3. Z-Wave’s Configuration Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)] Configuration Function Size Value Unit Default Description Parameter (Byte) Meter Report Command: [Command Class Meter,Meter Report,Rate Type+Meter Type,Precision+Scale+ Size,Meter Value 1,Meter Value 2] True Period 0-120 100ms...
  • Page 5: Troubleshooting

    Example: Scale = 0x00 (KWh) AN158-2 Germany AN158-3 U.K. Precision = 1 Size = 4 Bytes (KW/h) Meter Value 1 = 0x00(W) Meter Value 2 = 0x01(W) Meter Value 3 = 0x11(W) Meter Value 4 = 0x70(W) Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value 3*256) + (Meter Value 4) = 70.1 (KW/h)
  • Page 6: Specification

    control the ON/OFF own ON/OFF switch When replacing old appliances with new once, the retailer is legally obligated to take Switch of the load attached Symptom Cause of Failure Recommendation back your old appliance for disposal at least for free of charge. The Module LED 1.

Table of Contents