  • Page 1 Wellness humidifiers for steam baths User manual I n t e g r a t e d C o n t r o l S o l u t i o n s & E n e r g y S a v i n g s...
  • Page 3 The technical specifications shown in the manual may be changed without prior warning. The liability of CAREL in relation to its products is specified in the CAREL general contract conditions, available on the website www.carel.com and/or by The CAREL humidifiers are advanced products, whose operation is specified specific agreements with customers;...
  • Page 5: Table Of Contents

    8.5 Alarm history .....................30 STEAM DISTRIBUTION TABLE OF ALARMS 3.1 CAREL jet distributors (SDPOEM00**) ..........13 3.2 CAREL linear distributors for air ducts (DP***DR0) ....13 10. MAINTENANCE AND SPARE PARTS 3.3 Steam hoses ......................14 3.4 Condensate drain hose ................14 10.1 Spare parts for models UE001 to UE018 ..........33 10.2 Spare parts for models UE025 to UE065 ..........35...
  • Page 7: Introduction And Assembly

    1. INTRODUCTION AND ASSEMBLY 1.1 humiSteam Wellness (UEW*) 1.3 Opening the packaging Range of isothermal immersed electrode humidifiers with liquid crystal make sure the humidifier is intact upon delivery and immediately display for the control and distribution of steam. notify the transporter, in writing, of any damage that may be due to careless or improper transport;...
  • Page 8: Wall-Mounting

    1.b, 1.c Wall-mounting Fig. 1.g Models UE001 to UE065 turn oval-shaped label with the Carel logo, revealing the head of the earth screw below; remove the screw using a screwdriver; hold the cover by the sides and tilt; remove the cover by moving to the bottom;...
  • Page 9: Fitting The

    98C565P009 of wall-mounting; connectors for the electronic turn the red oval-shaped plate with the CAREL logo, revealing the board fastening hole below; slip the cover onto the frame (keeping it slightly oblique), until it rests on the rear edges, paying attention to the positioning holes on the side;...
  • Page 10: Water Connections

    If, on the other hand, the humidifier is supplied when boiling. with water from a Carel reverse osmosis system connected to the potable water supply network, the double check valve must be installed on the inlet to the reverse osmosis system.
  • Page 11 Fittings provided for the water connections: Modelli UE001…UE018 Modelli UE025…UE065 Key: supply water inlet drain water outlet bottom tank drain water outlet (models UE025 to UE065 only) Fig. 0.aFig. 2.b Hydraulic interfaces dimensions Interfaces dimensions drain/fill dimensions UE001 a UE018 mm (inc) 72.6 (28.6) D’...
  • Page 12: Supply Water

    2.1 Supply water Only use mains water with: • pressure between 0.1 and 0.8 MPa (14.5 and 116 PSI), temperature between 1 and 40 °C (33.8 and104 °F) and an instant flow-rate no lower than the rated flow of the fill solenoid valve, the connection is G3/4M (see par.
  • Page 13: Steam Distribution

    60 (2.4”) 68 (2.7”) 77 (3.0”) 99 (3.9”) Tab. 3.aTab. 3.a 3.2 CAREL linear distributors for air ducts (DP***DR0) Important: Important: Install away from obstacles (curves, branches, changes in cross-section, fit the distributor at a slight incline (at least 2°, to prevent the return grills, filters, fans).
  • Page 14: Steam Hoses

    3.3 Steam hoses Final checks • use CAREL hoses (max. 4 m long, see “Models of steam hoses”, page 41). the steam outlet hoses run upwards and the distributor has a Rigid pipes may break and cause steam leaks; minimum incline of 2° upwards (see Fig. 3.c);...
  • Page 15: Electrical Connections

    4. ELECTRICAL CONNECTIONS 4.2 Power cable connection 4.1 Preparing the electric cableways Before making the connections, ensure that the machine is Models UE001 to UE018 disconnected from the mains power supply. Check that the power supply voltage of the appliance corresponds to outside unit, bottom view inside unit, top view the value indicated on the rating plate inside the electrical panel.
  • Page 16 HUMIDISTAT (ON/OFF action) CONTROL WITH TWO CAREL PROBE • • connect outputs M7.1 and M7.2 to a humidistat jumper outputs M2.7 and M2.8 or connect to a remote contact • • jumper outputs M2.7 and M2.8 connect outputs M2.1, M2.2 and M2.3 to main probe •...
  • Page 17: Alarm Contact (M6.1 - M6.3)

    • room: code ASET030001 Contact available for the remote signalling of one or more alarms. If non-CAREL probes are used, check: • voltage signal: 0 to 1 Vdc, 0 to 10 Vdc, 2 to 10 Vdc, terminal M2.1 (GND: NC C M2.2);...
  • Page 18 M2.7 and M2.8 are connected by jumper or connected to an enable-operation contact; if non-CAREL probes are used: the earth of the probes is electrically connected to the humidifier board earth; if the humidifier is controlled by an external control device, the earth of the signal is electrically connected to the controller earth.
  • Page 19: Remote Display Terminal

    Wellness 0907858AXX) (see Fig. 5.a); • up to 200 metres: two CAREL TCONN6J000 boards, 6-wire telephone cables and an AWG20-22 shielded cable with 3 twisted pairs (for the connection of the two boards, Fig. 5.b). Note: to fill the empty space left by the display terminal on the humidifier, use CAREL kit code HCTREW0000.
  • Page 20: Control Of Production From Serial Port (Bms)

    Operate as follows: • Parameter “Installer / Supervisor / Supervisor (2/2) / Reg. from BMS ‘: default off, set to ON (or via serial non-volatile digital serial Variable 80: default 0, set to 1) • Variable volatile serial Full 31: Set a value between 0 and 1000: Proportional: tenths of a percentage, Temper: tenths of °...
  • Page 21: Starting And User Interface

    5. STARTING AND USER INTERFACE Before starting the humidifier, check: Press DOWN to select the number corresponding to the desired function and then ENTER to confirm. Press ESC repeatedly to return to the “Main” screen. water connections: Fig. 2.a page 10. In the event of water leaks do not start the humidifier before having resolved the problem;...
  • Page 22: Keypad

    5.4 Keypad 5.6 “Main” screen Fig. 5.c Fig. 5.a button function symbol function alarm LED red lit: list active alarms set point temperature( can be modified using the UP or DOWN LED red Flashing: alarm list automatically covered button) return to the “Main Menù” screen 2 (*) temperature inside the steam (measured by the probe/probes) light on inside the steam bath...
  • Page 23: Info" Screen (Read-Only)

    If enabled time bands, and you want to change the state machine (OFF 5.8 “INFO” screen (read-only) ON), or the setpoint, the following screen appears: Series of read-only screens for displaying the main humidifier status values. To access, press PRG from the “Rapid Selection” screen. There are 2 Regolation tmed range “INFO”...
  • Page 24: Alarms" Screen

    5.9 “Alarms” screen 2.Fans Fans ( 1/3) FAN SUPPLY Enable Fan Mode Fan threshold Turn on delay Turn off delay Fans ( 2/3) FAN EXTRACT Enable Fan Mode Turn on delay Turn off delay Fans ( 3/3) DRYING Fig. 5.e Enable drying Fans Indicates an alarm is active, press to display.
  • Page 25 Supervisor (2/2) Enable supervisory ON/OFF Enable supervisory regulation 6. GSM text on mask send mobile number modem status field alarm modem 1. Config. Config.restore (1/2) Maintenance restore Save configuration Load configuration Nominal Values Restore default parameter Humidifer type ... Kg/h ... V . Ph Config.restore (2/2) Delete Alarm History...
  • Page 26: User Menu

    6. USER MENU From the main screen press: it is possible the selection of 3 bands on and off and change the set point • PRG to access the main menu, within 24h. • ENTER to select and access the menu user. User menu screens: 1.keyboard lock day: LUN...
  • Page 27: Installer Menu

    7. INSTALLER MENU From the main screen press: 7.2 Utilities configuration • PRG to access the main menu, 1. Essence • DOWN to select the installer menu, • 2. Fans ENTER, • enter the password “77”, 3. Sanification 4. Light •...
  • Page 28: Functional Options

    In AUTO mode and type PERIODIC, the fan operation is independent of 7.3 Functional options steam but is active for the ON time (T ON) and off to the OFF time (T OFF) selectable. Functional options (1/3) parameter range default U.M. description In AUTO mode and type Programs (active only if scheduler enabled), the cylinder duration...
  • Page 29: Supervisory

    SMS format; • the SMS messages are subject to the charges and conditions of the SIM card network operator. CAREL declines all liability for the failure to send or receive SMS. “Wellness” +0300060EN - rel. 1.6 - 29.04.2022...
  • Page 30: Maintenance Menu

    8. MAINTENANCE MENU Important: the operations described in this menu must only be 8.3 Manual procedure carried out by qualified personnel. Important: these operations must only be performed by qualified From the main screen press: personnel, incorrect use may cause serious damage. •...
  • Page 31: Table Of Alarms

    In these conditions, pressing the alarm button once displays the type of the alarm relay output can be reset automatically or manually, according alarm (and the code, in line with the CAREL humidifier standard). to the type of fault, while the message displayed is reset manually (see the table below).
  • Page 32 alarms displayed meaning cause solution reset alarm relay consequence Warning: EA Foam alarm excessive foam in 1. flush the water supply lines; Manual signal only Foam the cylinder when 2. clean the cylinder, make sure a active Cylinder boiling softener is not used (if so, use another source of water or reduce the softening).
  • Page 33: Maintenance And Spare Parts

    10. MAINTENANCE AND SPARE PARTS 10.1 Spare parts for models UE001 to UE018 fill tank internal tubing kit fill solenoid valve kit cylinder manifold with drain pump plastic base plastic humidifier top TAM (transformer for measuring the current) transformer contactor fuse holder F1-F2 pCOe expansion board ( controller I/O expansion ) electronic controller...
  • Page 34 Table of water circuit, electrical and electronic spare parts, UE001 to 018 Water circuit Electrical and electronics Fill tank + Assembled f/d Trasformatore Fill solenoid Internal Plastic Plastic Display TAM (current description conductivity manifold + 230 alimentazione: valve kit tubing kit humidifier base humidifier top terminal...
  • Page 35: Spare Parts For Models Ue025 To Ue065

    10.2 Spare parts for models UE025 to UE065 Key: drain circuit fill solenoid valve kit internal tubing kit conductivity meter drain pump kit manifold drain pump hose cylinder TAM (transformer for measuring the current) contactor transformer pCOe expansion board ( controller I/O expansion ) pump control relay fuse holder electronic controller...
  • Page 36 Table of water circuit, electrical and electronic spare parts, UE025 to UE065 description spare part number pos. figure UE025 UE035 UE045 UE065 230 V 400 V 230 V 400 V Water circuit Drain pump hose UEKDH00000SP UEKDH00000SP UEKDH00000SP UEKDH00000SP UEKDH00000SP UEKDH00000SP 11.c Manifold UEKCOLL000SP...
  • Page 37: Cleaning And Maintenance Of The Cylinder

    After extended operation, or when using water rich in salts, the solid deposits that naturally form on the electrodes may grow until attaching CAREL is available for further support in case of doubts or in case more to the inside wall of the cylinder. If these deposits are conductive the heat...
  • Page 38: Cylinder Connection, Three-Phase Models Ue001 To Ue065

    10.5 Cylinder connection, three-phase 10.6 Cleaning and maintenance of the other models UE001 to UE065 components Important: production conductivity (μS/cm) power supply (V) (kg/h) • when cleaning plastic components do not use detergents or solvents; • 75/350 μS/cm scale can be removed using a solution of 20% acetic acid and then 350/1250 μS/cm rinsing with water.
  • Page 39: Wiring Diagrams

    11. WIRING DIAGRAMS 11.1 Diagram of single-phase models UE001 to UE009 Key: terminal block transformer high level electrodes contactor conductimeter manual switch F1-F2 primary fuses F5-F6 PCOe fuses fill valve fuse protection drain pump external TAM drain pump secondary fuses Fig.
  • Page 40: Diagram Of Three-Phase Models Ue003 To Ue018

    11.2 Diagram of three-phase models UE003 to UE018 key: terminal block transformer high level electrodes contactor manual switch conductimeter F1-F2 primary fuses fill valve F5-F6 PCOe fuses fuse protection drain pump drain pump external TAM secondary fuses Fig. 11.b (**) Attention: for TAM configurations and connections see par. 12.1 “Wellness”...
  • Page 41: Diagram Of Three-Phase Models Ue025 To Ue065

    11.3 Diagram of three-phase models UE025 to UE065 Key: terminal block transformer high level electrodes contactor manual switch conductimeter F1-F2 primary fuses fill valve F5-F6 PCOe fuses fuse protection drain pump drain pump external TAM secondary fuses Utenze / Utilities Fig.
  • Page 42: General Features And Models

    TAM configurations and connections (transformer for measuring the current) Important: the configurations and connections are already made by CAREL, and no changes are required. The following diagrams represent possible connection modes and may be useful in the event of serious electrical malfunctions on the humidifier.
  • Page 43: Technical Specifications

    (2x1.6”) 1/1.5 max. capacity kg/h (lb/h) (2.2/3.3) (6.6) (11) (17.6) (19.8) (22) (33) (39.7) (55.1) (77.2) (99.2) (143.3) CAREL steam hoses code ID mm (in) 1312360AXX 22 (0.9”) √ √ 1312365AXX 30 (1.2”) √ √ √ √ √ √ 1312367AXX 40 (1.6”)
  • Page 44: Models Of Concentrated Jet Steam Distributors

    ** = use CAREL “Y” kit code UEKY000000 (40 mm/1.6” inlet and 2 x 30 mm/1.2” outlets) *** = use one CAREL “Y” kit code UEKY40X400 (40 mm/1.6” inlet and 2 x 40 mm/1.6” outlets) and two CAREL “Y” kit code UEKY000000 (40 mm/1.6” inlet and 2 x 30 mm/1.2”...
  • Page 45: Controlling The Board Via Network

    DO NOT CONFIGURE VA-RIABLES THAT ARE NOT SHOWN IN THE TABLE, OTHERWISE THE OPERATION OF THE HUMIDIFIER MAY BE AFFECTED. “A” Read (R)/ Data Variable name Analogue variables* (Modbus®: REGISTERS) Def. CAREL - Write (W) type Modbus® Probe1_Value Probe 1 value (based on the selected unit of measure) 32767...
  • Page 46 “ D “ Read (R)/Write Variable name Digital variables (Modbus®: COILS) Default Data type CAREL - Modbus® Power1 Contactor Boolean Fill1 Fill Boolean Drain1 Drain Boolean en_bms_on_off Enable ON/OFF from supervisor Boolean En_Reg_From_Superv Enable control from supervisor Boolean Dehumid_Status Dehumidification status on/off...
  • Page 47 “ D “ Read (R)/Write Variable name Digital variables (Modbus®: COILS) Default Data type CAREL - Modbus® Inlate_Type Supply fan operating mode (Manual; Automatic) 0 Boolean Inlate_On_Off Activate supply fan in ON/OFF mode Boolean En_Scheduler enable scheduler Boolean Inlate_On_Off Activate supply fan in ON/OFF mode...
  • Page 48 “I” Read (R)/Write Data Variable name Integer variables (Modbus®: REGISTERS) Default type CAREL Modbus® H_Sw_Version High part of the software version 32767 Integer L_Sw_Version Low part of the software version 32767 Integer Voltage_Type Humidifier rated voltage in [V] 32767 Integer...
  • Page 49 “I” Read (R)/Write Data Variable name Integer variables (Modbus®: REGISTERS) Default type CAREL Modbus® Reg_Superv_Value send control signal (0-1000, temp: tenths of 1000 Integer °C/°F, humid: tenths of rH%). Set_Prod_Essence Percentage with respect to set point for Integer defining the activation band...
  • Page 50: Technical Appendix

    13. TECHNICAL APPENDIX Independent control with temperature probe (see Fig. 13.1 Operating principle 13.b) Immersed electrode humidifiers manufacture steam by boiling the The production of steam is related to the reading of the probe and water contained inside the cylinder. The heat required to boil the water increases as the temperature value read decreases.
  • Page 51: Supply Water Conductivity

    The complete washing of the cylinder can be disabled, so as to guarantee steam production, even if reduced, in applications where continuity of service is required (installer menu > drain options > disable complete emptying for foam). CAREL reserves the right to modify or change its products without prior notice.
  • Page 52 Agenzia / Agency: CAREL INDUSTRIES HQs Via dell’Industria, 11 - 35020 Brugine - Padova (Italy) Tel. (+39) 049.9716611 - Fax (+39) 049.9716600 e-mail: carel@carel.com - www.carel.com...