Led Status Indicator, Display & Function Key - Siemens SIMATIC RTLS4083T Operating Manual

Localization systems
Hide thumbs Also See for SIMATIC RTLS4083T:
Table of Contents

Advertisement

Device description
2.3 LED status indicator, display & function key
2.3
LED status indicator, display & function key
The operating states of the transponder are indicated by the LEDs. The states can be off , on
and flashing .
Table 2-3
LED
Note
Observe the notes in sections "RTLS4083T operation (Page 17)" and "Charging instructions for
the RTLS charging station (Page 18)".
Table 2-4
Display
Display
F1 function key
10
LED status indicator
Meaning
Lights up green once for 1.5 seconds when the transponder is restarted.
Briefly flashes green once when the F1 function button is pressed, the battery voltage is
sufficient and the transponder is outside of the charging station or the Power mounting clip.
Continuously flashes green when the transponder is fully charged and in the charging station
or the Power mounting clip.
Lights up green when the transponder is fully charged and in the charging station or the Power
mounting clip.
Briefly flashes red once when the F1 function button is pressed, the battery voltage is low and
the transponder is outside of the charging station or the Power mounting clip. However, the
transponder is available and localizable.
Flashes red (user LEDs flash) if you trigger flashing via the Locating Manager. You can config‐
ure the duration and frequency of flashing via the Locating Manager.
Note that error states may not be detected by the user LED flashing.
Continuously flashes red when the transponder is in the charging station or the Power mount‐
ing clip and the battery is defective.
Remove the transponder from the charging station or the Power mounting clip immediately
and do not recharge this transponder. Contact customer service.
Lights up red if there is an error during charging.
Display and function key
Meaning
5 background images can be saved
20 text fields with 58 characters each
20 fonts and font sizes, including bar codes
If this function key is pressed, the message is forwarded to the program interface.
When the F1 function button is pressed, the charge state of the battery is evaluated
and, depending on its voltage, the LED briefly flashes green or red. In the Locating
Manager, you can configure a transponder parameter to define the threshold value
below which the battery voltage is defined as too low for operation, a "low power"
message is generated and the LED flashes red. Refer to the notes in the section
"RTLS4083T operation (Page 17)".