Key
A0080
A0100
A0400
GB
A4000
A8000
Key
F00
00
F05
00
07
F07
00
01
F11
00
90
Warning messages
Max. motor temperature reached, check motor and sensor.
Mains phase failure, check mains fuses and supply cable.
Limit frequency reached; output frequency is limited.
DC link voltage has reached the type-specific minimum.
Application-specific warning: For detailed functions, refer to Operating
Instructions.
Current Error 259 and Last Error 310 make troubleshooting
easier, an error code is displayed.
The error message can be acknowledged via the control unit
buttons and S1IND input.
Meaning
No fault has occurred.
Overloaded, check load situation and ramps.
Message from phase monitoring, check motor and wiring.
DC-Link Voltage
DC link voltage too high, check deceleration ramps and connected
brake resistor.
DC link voltage too low, check mains voltage.
Output frequency
Output frequency too high, check control signals and settings.