TALAMEX X Series Manual page 27

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
36-VOLT BATTERY CONNECTION
1. Starting with the negative (–) lead, disconnect the battery cables from the engine starting or accessory battery.
2. Install a 50-amp (good) or 60-amp (best) manual reset circuit breaker in line with the trolling motor power cable positive
(+) lead and the trolling motor battery C positive (+) terminal.
3. Connect the positive (+) trolling motor lead to the positive (+) terminal on trolling motor battery C.
4. Connect a jumper wire (reference gray) between the negative (–) terminal on battery C to the positive (+) terminal on
battery B.
IMPORTANT: The jumper wire should be the same wire gauge as the negative (–) and positive (+) power cables.
5. Connect a jumper wire (reference gray) between the negative (–) terminal on battery B to the positive (+) terminal on
battery A.
6. Connect the trolling motor negative (–) lead to the negative (–) terminal on battery A.
7. Starting with the positive (+) lead, reconnect the battery cables to the engine starting or accessory battery.
Wiring 36-volt battery connection
a –
power cables to trolling motor
b –
manual reset circuit breaker
c –
jumper wire (not supplied)
d –
negative (-) battery terminal
Wire color code abbreviations
BLK = Black
BLU = Blue
BRN = Brown
GRY = Gray
GRN = Green
ORN or ORG = Orange
PNK = Pink
PPL or PUR = Purple
RED = Red
TAN = Tan
WHT = White
YEL = Yellow
LT or LIT = Light
DK or DRK = Dark
27