12-VOLT BATTERY CONNECTION (X-150 en X-180)
1.
Starting with the negative (–) lead, disconnect the battery cables from the engine starting or accessory battery.
2.
Install a 50-amp (good) or 60-amp (best) manual reset circuit breaker in line with the trolling motor power cable positive
(+) lead and the trolling motor battery positive (+) terminal.
3.
Connect the positive (+) trolling motor lead to the positive (+) trolling motor battery terminal.
4.
Connect the negative (–) trolling motor lead to the negative (–) trolling motor battery terminal.
5.
Connect a common ground bond from the trolling motor battery negative (–) terminal to the engine
negative (–) terminal.
6.
Starting with the positive (+) lead, reconnect the battery cables to the engine starting or accessory battery.
Wiring 12-volt battery connection
24-VOLT BATTERY CONNECTION
1. Starting with the negative (–) lead, disconnect the battery cables from the engine starting or accessory battery.
2. Install a 50-amp (good) or 60-amp (best) manual reset circuit breaker in line with the trolling motor power cable positive
(+) lead and the trolling motor battery B positive (+) terminal.
3. Connect the positive (+) trolling motor lead to the positive (+) terminal on trolling motor battery B.
4. Connect a jumper wire (reference gray) between the negative (–) terminal on battery B to the positive (+) terminal on
battery A.
IMPORTANT: The jumper wire should be the same wire gauge as the negative (–) and positive (+) power cables.
5. Connect the trolling motor negative (–) lead to the negative (–) terminal on battery A. Starting with the positive (+) lead,
reconnect the battery cables to the engine starting or accessory battery.
6. Starting with the positive (+) lead, reconnect the battery cables to the engine starting or accessory battery.
Wiring 24-volt battery connection
26
starting battery
a –
power cables to trolling motor
b –
manual reset circuit breaker
c –
trolling motor battery
d –
engine starting or accessory battery
e –
power cables to engine
f –
common ground bond
a –
power cables to trolling motor
b –
manual reset circuit breaker
c –
jumper wire (not supplied)
d –
negative (-) battery terminal