ICPDAS RS Series User Manual page 80

Hide thumbs Also See for RS Series:
Table of Contents

Advertisement

Industrial Redundant Ring Switch – RS Series User Manual
Table – 10 Corresponding bits and system status (for svalue)
Table – 11 Displayed hexadecimal number and current system status conditions
Table – 12 Corresponding bits and jumpers
qq
bit
Corresponding to:
0
Power 1
1
Power 2
2
Master Ring Switch
indicator
3
Relay output status
Returned
Corresponding 8 bits
svalue in
binary numbers
hexadecimal
format
0
00000000
1
00000001
2
00000010
3
00000011
4
00000100
5
00000101
6
00000110
7
00000111
8
00001000
9
00001001
0A
00001010
0B
00001011
0C
00001100
0D
00001101
0E
00001110
0F
00001111
Bit 3
Bit 2
Jumper 3
Jumper 4
1
on
1
0
off
0
TDRS4050601
Condition
Description
a
If there is a power fail
occurring on Power 1, bit 0
will be set as 1.
b
If there is a power fail
occurring on Power 2, bit 1
will be set as 1.
c
If his Switch is the master
Ring Switch(the Master
LED indicator will be "on")
bit 2 will be set as 1.
d
If the relay output is
activated, bit 3 will be set
as 1.
Showing current
system status
condition(s):
a
b
c
a or b
c
a or c
b or c
a or b or c
d
a or d
b or d
a or b or d
c or d
a or c or d
b or c or d
a or b or c or d
Bit 1
Bit 0
Jumper 5
Jumper 6
on
1
on
1
off
0
off
0
on
off

Advertisement