Industrial Redundant Ring Switch – RS Series User Manual
lmask [mask value]
Description
Parameters
Example:
cmask [mask value]
Description
This command enables you to configure relay output activation status when there is
link loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0
corresponds to port 1, etc. (Please refer to Appendix G, Table – 1.) If the mask bit of
that port(s) is specified by being set up as 1, when there is a link loss occurring on
that port(s), relay output will be activated. The mask value is in hexadecimal format
that represents the 8 bits corresponding binary numbers, it can be either in the form
of initiating "0X" plus a suffix of the hexadecimal number or eliminating "0X"; simply
the hexadecimal number itself. If a mask value is not specified, the "lmask"
command will display previous assigned mask value.
To assign a mask value for activating relay output when there is link loss occurring
on the port(s), please refer to Appendix G, Table – 2.
Parameter
Description
mask value
Provides the mask value that you want to specify to
configure status of relay when link loss occurs
This command enables you to configure relay output activation status when there is
communication loss occurring on port(s). The ports are corresponding to the 8 mask
bits, bit 0 corresponds to port 1, etc. (Please refer to Appendix G, Table – 3.) If the
mask bit of that port(s) is specified by being set up as 1, when there is a
communication loss occurring on that port(s), relay output will be activated. The
mask value is in hexadecimal format that represents the 8 bits corresponding binary
numbers, it can be either in the form of initiating "0X" plus a suffix of the hexadecimal
number or eliminating "0X"; simply the hexadecimal number itself. If a mask value is
not specified, the "cmask" command will display previous assigned mask value.
To assign a mask value for activating relay output when there is communication loss
occurring on the port(s), please refer to Appendix G, Table – 4.