Connecting Fiber Ports (only for models with fiber port)

The automatic MDI/MDI-X crossover function does not apply to fiber connections, as
these must be crossed over manually. To connect the fiber port on one switch to the fiber
port of another switch, simply cross-connect the transmit channel at each end to the
receive channel at the opposite end as illustrated in the figure below.
These models have two 100Base-FX ports with SC type connectors (in multi-mode and
single mode versions).
The following table describes the Fiber Ports LEDs
Color
RS Switch offer a relay contact output on Terminal Block of the Switch equipment (refer
page 18) . It is able to connect to a light, buzzer ...etc. warning device and notify system
failures immediately configure the relay warnings of Power, Link Lose and
Communication Lose (refer page K , lmask ).
Link Lose
Set relay active if port disconnected, such as, no cable connected; cable break; opposing
device fail.
Communication Lose
Set relay active if port of the ring pair disconnected.
23
State
ON
P1_Link
Link
P2_Link
Link
OFF
Not Link
Not Link
TDRS4050601
BLINK
Transmission
Transmission