Galvin Engineering GalvinAssist CP Installation Instructions Manual

Hand shower kit

Advertisement

Quick Links

Product Installation Guidelines
GalvinAssist
SS Hygienic G/Rail, ClevaCare Shw & CliniLever Tap
PRODUCT CODES:
-
CLEVAKIT1CP
SPECIFICATIONS
-
CP Brass swing arm with stainless steel spring.
-
Supplied with stainless steel fasteners.
-
Finished in bright chrome plate for easy cleaning and added durability.
IMPORTANT: All Galvin Engineering taps are tested in accordance with AS/NZS 3718 and leave our
premises in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change
without notice.
TOOLS REQUIRED
Power drill
Spanner or adjustable crescent
Hex Key
Thread Tape
© Galvin Engineering Pty Ltd
®
CP Hand Shower Kit W/-900 x 32
Version 1, 25
½" BSP – Female
Handheld Shower
Ceramic Cartridge
Min
150
Max
500
Min
5
Max
55
8.24
Chrome
th
May 2022, Page 1 of 6

Advertisement

loading

Summary of Contents for Galvin Engineering GalvinAssist CP

  • Page 1 CP Brass swing arm with stainless steel spring. Supplied with stainless steel fasteners. Finished in bright chrome plate for easy cleaning and added durability. IMPORTANT: All Galvin Engineering taps are tested in accordance with AS/NZS 3718 and leave our premises in good working order. TECHNICAL DATA ½”...
  • Page 2 If the mounting holes do not already exist, mark out and drill the holes as shown in rough- in dimensions. For Tapware 0 to 15mm Wall body − Wall body must be G5/8” FI and body should be between 0 and 15mm behind the finished wall surface. G 5/8” © Galvin Engineering Pty Ltd...
  • Page 3: Installation

    May 2022, Page 3 of 6 INSTALLATION INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these Version 1, 1 June 2022, Page 3 of 6 installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements.
  • Page 4 Refit threaded sleeve and spindle. The ¼ turn ceramic head part MUST be fitted into the wall body prior to refitting the threaded sleeve and spindle. DO NOT tighten cartridge by using the spindle or the threaded sleeve. © Galvin Engineering Pty Ltd...
  • Page 5: Troubleshooting

    Handle is loose Screw has come loose Tighten handle screw Flange does not screw Wall bodies are set too far out Re-position tap bodies down onto wall surface © Galvin Engineering Pty Ltd...
  • Page 6: Warranty

    The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.