1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
1.0

INTRODUCTION

The CliniMix
®
CP-BS Inwall Thermo Progressive ShowerMixer with GalvinCare Handle W&C is a high-performance
thermostatic mixing valve suitable for a wide range of applications. The mixing valve has the following features:
This progressive shower mixer provides state of the art features to comply with healthcare requirements.
®
The GalvinCare
Suitable for high and low pressure systems with a thermostatically controlled water temperature of 48°C
maximum.
Enables water to be mixed closer to the point of discharge, minimising stagnant warm water which
provides ideal conditions for legionella bacteria to grow.
Smooth internal components and body reduces scale build-up and bacteria growth.
Maximum temperature limiter fitted for protection from accidental scalding.
Clean smooth lines facilitate fast and easy cleaning.
All servicing and commissioning can be done without removing the device. Easy access isolators, help
minimise time spent on commissioning and maintenance.
Designed to provide stable mixed temperature with rapid shut down in the event of cold or hot water supply
failure.
Approved to: AS/NZS 4032.4.
IMPORTANT: All GalvinCare
premises in good working order. Document to be read in conjunction with CliniMix
Valve manual.
paddle handle provides straight forward temperature control and minimises ligature risk.
®
mental health taps are tested in accordance with AS/NZS 3718 and leave our
Version 2, 31 October 2019, Page 1 of 16
®
Progressive Thermostatic Mixing
1
2
2
2
2
3
3
5
6
7
8
9
10
10
11
12

Advertisement

Table of Contents
loading

Summary of Contents for Galvin Engineering CliniMix CP-BS

  • Page 1: Table Of Contents

    Version 2, 31 October 2019, Page 1 of 16 ® CliniMix CP-BS Inwall Thermo Progressive Shower Mixer with GalvinCare Handle W&C PRODUCT CODE: - WM-TMVPMSCS TABLE OF CONTENTS INTRODUCTION TECHNICAL DATA SAFETY DESCRIPTION DIMENSIONS WATER SUPPLY CONDITIONS INSTALLATION OPERATION AND TESTING COMMISSIONING 10.0 ISOLATE INLETS AND CLEAN FILTERS...
  • Page 2: Technical Data

    Version 2, 31 October 2019, Page 2 of 16 TECHNICAL DATA ½” B P – Male Inlet ½” B P – Male Outlet Headwork Thermostatic mixing valve Working Pressure Range (kPa) Working Temperature Range (°C) Finish Chrome Wall Recess required (mm) Ø157 x 6 NOTE: Galvin Specialised continually strive to improve their products.
  • Page 3: Water Supply Conditions

    Version 2, 31 October 2019, Page 3 of 16 WATER SUPPLY CONDITIONS Version 3, 14 December 2018, Page 3 of 16 INTRODUCTION ® This CliniMix CP-BS Inwall Thermo Progressive ShowerMixer w/ GalvinCare Handle W&C is manufactured to the highest standards. When installed the supply conditions detailed below must be observed. SUPPLY REQUIREMENTS This mixer is designed to be installed on all types of plumbing systems.
  • Page 4 INSTALLATION IMPORTANT: Galvin Engineering products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 5: Operation And Testing

    Version 2, 31 October 2019, Page 5 of 16 Version 3, 14 December 2018, Page 5 of 16 3. Seal outer faceplate and fit inner faceplate 4. Secure flange − Seal the outer faceplate to the wall using a − Secure the flange with the three supplied screws. −...
  • Page 6: Commissioning

    Version 2, 31 October 2019, Page 6 of 16 COMMISSIONING Version 3, 14 December 2018, Page 6 of 16 Initial Test for Correct Operation The following must be checked to ensure the correct performance of the progressive thermostatic mixer: − the supply pressures and temperatures are within the range of operating pressures and temperatures for the thermostatic valve.
  • Page 7: Isolate Inlets And Clean Filters

    Version 2, 31 October 2019, Page 7 of 16 Shut Down Test 2 With the mixer still set in full hot position and with both supplies turned on allow the flow to stabilise for at Version 3, 14 December 2018, Page 7 of 16 least 15 seconds and record the temperature.
  • Page 8: Adjustment Of The Mix Temperature

    Version 2, 31 October 2019, Page 8 of 16 Version 3, 14 December 2018, Page 8 of 16 Fit the inner faceplate into the outer faceplate. 8. Fit the handle and fasten so the arrow shape on Ensure the marking on the top of the plate is top of the handle matches the marking on the positioned correctly.
  • Page 9: Removing And Inspecting Mixer Cartridge

    Version 2, 31 October 2019, Page 9 of 16 12.0 REMOVING AND INSPECTING MIXER CARTRIDGE Version 3, 14 December 2018, Page 9 of 16 1. Remove handle assembly 2. Remove flange and faceplate − Unscrew the three screws and pull out the flange −...
  • Page 10: Maintenance

    Version 2, 31 October 2019, Page 10 of 16 13.0 MAINTENANCE Thermostatic Mixing Valves are precision products and as such any maintenance needs to be undertaken in Version 3, 14 December 2018, Page 10 of 16 e n env r nment nd n rd n e w th the m nuf turer’s nstru t ns The purpose of servicing regularly is to monitor any changes in performance due to changes in either the...
  • Page 11: Troubleshooting

    Version 2, 31 October 2019, Page 11 of 16 15.0 TROUBLESHOOTING PROBLEM CAUSE RECTIFICATION Version 3, 14 December 2018, Page 11 of 16 − Hot and cold supplies are fitted to − Refit the valve with hot/cold supplies fitted to The desired mixed water temperature cannot be the wrong connections.
  • Page 12: Warranty

    12 months service life, and if found by Galvin Engineering to be so defective will be replaced as set out below. If the product is sold by a party other than Galvin Engineering, then it is sold by the seller as principal and the seller has no authority from Galvin Engineering to give any additional warranty on behalf of Galvin Engineering.
  • Page 13 Galvin Thermostatic Mixing Valve or Tempering Engineering Version 3, 14 December 2018, Page 13 of 16 Valve Commissioning Report and/or Maintenance Report Note: Please use a separate form for each valve. The original copy of the report is to be given to the owner/occupier and retained on site for a minimum of 7 years. □...
  • Page 14 Galvin Engineering Thermostatic Mixing Valve or Tempering Version 3, 14 December 2018, Page 14 of 16 Valve Commissioning Report and/or Maintenance Report Test Results □ □ Valve considered satisfactory for use: Yes If No, state the reason and action taken:...
  • Page 15 Galvin Engineering Thermostatic Mixing Valve or Tempering Valve Commissioning Report Version 3, 14 December 2018, Page 15 of 16 Valve Location/Building : ____________________________________________________ Room or Area: ____________________________________________________________ Work Order No.:___________________________________________________________ Warm Flow rate of Design Water (LPS) Temp of Warm Water (C)
  • Page 16 Galvin Engineering Thermostatic Mixing Valve or Tempering Version 2, 31 October 2019, Page 16 of 16 Valve Commissioning/Maintenance Report The following information is to be provided by the site manager/owner/occupier. Valve size and installation recommended by : ___________________________________________________ Valves supplied by: ________________________________________________________________________ Date of Installation: _________________________ Drawing No.

Table of Contents