CVPM02, CVPM05, CVFM04 User Guide
Monitor and Manage CacheVault Modules
This chapter explains how to monitor and manage the MegaRAID CacheVault modules used with the MegaRAID
SAS controllers. You can use the following Broadcom MegaRAID utility programs to retrieve status information for CVPMs
used with MegaRAID controllers:
Storage Command Line Tool (StorCLI)
The command line management software designed for the MegaRAID product line.
Human Interface Infrastructure (HII) configuration utility
A tool for configuring controllers, physical disks, and virtual disks, and for performing other configuration tasks in a
pre-boot, Unified Extensible Firmware Interface (UEFI) environment.
For more information about CacheVault functions in these utilities, refer to the MegaRAID SAS Software User Guide,
which applies to 6Gb/s MegaRAID controllers, or the 12Gb/s MegaRAID SAS Software User Guide for 12Gb/s MegaRAID
controllers.
Monitor CacheVault Module Information in StorCLI
The StorCLI utility supports the following CacheVault command, which identifies the specific controller to which a
CacheVault module is connected:
storcli /cx/cv show all
The object identifier /cx/cv refers to the CacheVault module on controller x. Only one CacheVault module can connect
to a controller at a time.
NOTE
This command works only when a CacheVault module is connected to the controller; otherwise, an error
message appears.
Input example: storcli /c0/cv show all
where, c0 identifies controller number 0.
Monitor CacheVault Module Information with the HII Configuration
Utility
You can use the HII Configuration utility to display information about the CVPM on the following Battery Management
screen. <SuperCaP> in the Type field refers to the CVPM.
Broadcom
CVPM02, CVPM05 Power Modules | CVFM04 Cache Module
CVPM02-05-CVFM04-UG101
18
Need help?
Do you have a question about the CVPM02 and is the answer not in the manual?