Maintenance And Cleaning; Safety Precautions; Ppe Features; Maintenance - Astoria STORM BARISTA ATTITUDE SAEP 2GR Use And Maintenance Manual

Hide thumbs Also See for STORM BARISTA ATTITUDE SAEP 2GR:
Table of Contents

Advertisement

10.

MAINTENANCE AND CLEANING

Safety precautions

10.1
Carefully read the instructions provided in chapter "I. SAFETY
PRECAUTIONS" on page 3.

PPE features

10.2
When maintaining and cleaning the machine, the
following PPE is required:
Component
PRESSURE TRANSDUCER
FILTERS AND FILTER
HOLDERS
DISPENSING GROUP
WATER FILTER
WATER SOFTENER
GRINDER-DISPENSER
HEATING UNIT
HEATING UNIT
58
92
of
Type of operation
• Check the heating unit pressure, which must be between 0.8 and 1.4 bar.
• Check the water pressure when coffee is being dispensed: check the pressure
indicated on the gauge, which must be between 8 and 9 bar.
Check the condition of the filters. Check for any damage on the edge of the filters
and check whether any coffee grounds settle in the coffee cup, and replace the filters
and/or filter holders, as required.
Replace the shower screen and group gasket as indicated in para. "10.3.4 Dispensing
group maintenance" on page 60.
Replace the water filter cartridge at the frequency indicated by the manufacturer.
If limescale has formed in the hydraulic circuit, the filter will need to be replaced.
Carry out the regeneration as instructed by the manufacturer.
Take care in areas where the water is very hard. The water will need to be regener-
ated more frequently, especially if the machine is used intensively.
• Check the ground coffee dose (around 7 grams each time) and check the degree
of grinding. The grinders must always have sharp cutting edges. There will be too
much powder in the grounds when they are deteriorating.
• We recommend calling out the Maintenance Technician to replace the flat grinders
after every 400/500 kg of coffee, or after every 800/900 kg for conical grinders.
• If the automatic grinder wear warning is enabled, follow the instructions in para.
"8.3.5 Maintenance report" on page 41.
Replace the water in the heating unit as indicated in para. 6.6 on page 32.
• Replace the electric heating element if it becomes faulty or malfunctions.
• Do not replace the heating element with a more powerful one. Before making any
changes, please contact the Manufacturer.
• If the thermostat of the heating element is triggered, reset it by pressing the central
button of the thermostat. However, before starting the machine up again, check
what caused the problem.
• If the heating unit insulation needs to be removed, restore the insulation after the
maintenance work has been completed.
• Remove and clean the heating unit level probes.
• Check whether there is any limescale build-up on the heating element.
• If there is a lot of limestone build-up, this indicates that the water filter has not
been replaced, or that the softener has not been regenerated.
• When replacing any components, always replace the relative gasket as well.
The use of protective gloves is mandatory

Maintenance

10.3
10.3.1 Scheduled maintenance
Carry out scheduled maintenance according to the
instructions in the table below.
If the machine is used intensively, the checks need to
be performed more frequently. The envisaged operations
are outlined in the following pages.
Weekly
Quarterly
Yearly
X
X
X
X
X
X
X
X
TECHNICIANS manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storm barista attitude saep 3gr

Table of Contents