Attention: the switching times must always relate to one day, i.e.
a switching time may not exceed the 24 hour limit. Switching on
before midnight and switching off after midnight cannot be recog-
nised by the software. If a switching time of more than 24 hours
should be defined, then a switch-off time of 23:59 must be entered
for the first day, with a switch-on time of 0:00 for the following day.
3 different switching pairs can be defined for each block of days or
week day. If a target temperature is desired, select the field after the
time pair (for "Automatic" operating mode only) and then save.
Temperature range which can be set: 10 °C – 40 °C
or no temperature (---)
Factory setting: ---
"DATE/TIME" display
2 0
.
1 7
Time zone offset
Summer t ime off set i s done automa t i ca l l y
Fig. 3.27
Touch control panel – Setting the date and time
The change can be made by selecting the appropriate number field.
"CHILD LOCK" display
The "Child lock" can be activated in order to prevent unintentional changes
on the touch display. A lock appears as a symbol in the top right of the
display. The child lock is activated by pressing the time for 3 seconds. The
function is deactivated by repeatedly pressing the button.
15:32
Fig. 3.28
Touch control panel – Child lock
We reserve the right to make technical changes
0 7
. 2 0
2 1
:
1 0
1
h
next
17
Actual °C
AUTO mode
25
Desired °C
Ready
Party
"INFORMATION" display
07:12
SW Version
Service
op.hours
Ext. request
Fig. 3.29
Touch control panel – Displaying information
You can find the following information in this display:
ū The current software version (e.g. 2.02.17 L6)
ū Time to next service. The pellet fireplace must be serviced at regu-
lar intervals. A service is automatically requested after 2000 operating
hours. Call a service technician to carry out the service. The "Carry out
service" notification continues to appear until the service technician
carries out the service and resets the notification in the service menu.
ū Operating hours counter
ū External requirements
ū An external room thermostat can be connected as an "external re-
quirement". Since the internal room temperature sensor is also
still connected, the signal which switches first is used for regula-
tion. If the target temperature should be specified via the external
room thermostat, then the room temperature which can be set in
"Automatic" mode must be set to the maximum value (40 °C).
ū This display can be used to check whether the external room ther-
mostat has been connected correctly and is assuming regulation
of the pellet fireplace. "On" or "Off" must be shown on the display
when adjusting the room temperature to higher or lower than
the current room temperature on the room thermostat.
ū If no external components are connected, the "On" is always
displayed.
Operating keys in the "Information" display
SYSTEM INFO
Shows the most recent error messages
CURRENT INFORMATION
Display:
- Flame temperature
- Output stage
- Induced draft fan speed
- Vacuum
SERVICE MENU
Password protected area for service technicians
(Note: the specialist dealer can obtain the password for the
service menu from Olsberg customer service).
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
2.02.17L6
2000h
0h
off
83 | 154