Exhaust system and chimney design
min. 80
Fig. 2.13
Exhaust gas connection
We reserve the right to make technical changes
Chimney dimensions
The chimney dimensions are in accordance with DIN EN 13384 2
and in accordance with the country-specifi c regulations.
ARINA 2.0 6 kW / INARA 2.0 6 kW / LEVANA 2.0 6 kW
Nominal heat output .............................................................................. 6.0 kW
Partial heat output ................................................................................... 2.1 kW
Exhaust mass fl ow .....................................................................................5.5 g/s
EN 13384-2
Exhaust temperature at the nozzle ..................................................163.0 °C
Minimum pump pressure at nominal heat output ......................11.2 Pa
Minimum pump pressure at partial heat output ..........................10.3 Pa
LEVANA 2.0 8 kW
Nominal heat output .............................................................................. 8.0 kW
Partial heat output ................................................................................... 2.4 kW
Exhaust mass fl ow .....................................................................................6.0 g/s
Exhaust temperature at the nozzle ..................................................138.0 °C
Minimum pump pressure at nominal heat output ......................12.5 Pa
Minimum pump pressure at partial heat output ............................ 9.5 Pa
LEVANA AQUA 2.0 8 kW
Nominal heat output .............................................................................. 8.0 kW
Partial heat output ................................................................................... 2.4 kW
Exhaust mass fl ow .....................................................................................7.1 g/s
Exhaust temperature at the nozzle ...................................................129.4°C
Minimum pump pressure at nominal heat output ......................11.2 Pa
Minimum pump pressure at partial heat output ............................ 9.1 Pa
min. 80
Max. permissible water operating pressure ................................... 2.5 bar
● If the pump pressures are too high (> 20 Pa), then you should set
-P
● Set the required pump pressure at the exhaust gas outlet to 0 Pa
Multiple use of the chimney is possible with special approval
(contact the district master chimney sweep).
The chimney must correspond to a temperature class soot fi re resist-
ance of at least T400.
up pump pressure limitation (e.g. draft regulator in the chimney)!
for the chimney calculation!
Warning! Serious personal injury and environmental
damage owing to hazardous combustion gases!
Combustion gases in the installation room which occur as a
result of a blocked chimney are dangerous. The chimney, con-
nector and flue gas tract must be free from obstructions and
cleaned in accordance with the manufacturer's instructions.
Only permitted fuels may be used!
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0