Step
4
Cut the clamp and
release the harnesses
for thermistors from the
wire clamp material.
5
Cut the 3 clamps.
6
Remove the suction air
thermistor.
2. Remove the float switch.
1
Remove the 5 screws.
Removal Procedure
Procedure
Bottom view
Clamp
Wire clamp material
Clamp
Thermistors / Drain Pump / Float Switch
Points
 Remove the fan motor/fan
rotor and drain pan
beforehand.
 When reassembling,
harnesses for thermistors
should be bundled and fixed
with the wire clamp material.
(R25884)
Harnesses for
thermistors
Suction air thermistor
Clamp
 You can remove the float
switch and drain pump
without removing the fan
motor.
(R25886)
Wire clamp
material
(R25898)
(R25885)