5.5 "Frozen" appliance
If the ambient temperature is lower than 0
proceed as described below:
1. Disconnect the appliance from the mains.
2. Close the water tap.
3. Wash the tap with warm water (approx. 50
hose off.
4. Take off the hose and immerse it in warm water (approx. 50
5. Pour warm water (2 - 3 litres / approx. 50
10 minutes.
6. Reconnect the water inlet hose to the tap and check, that the water inlet and the
water drain works properly.
7. When you operate the appliance again, the ambient temperature must be higher
than 0
C.