Troubleshooting an HVAC/HVDC Power Supply Unit

e) Turn the power switch to ON (or 1).
f) Verify that the Output LED turns on.
Step 7
If the Output LED is still not on, verify that the power supply unit is functional by replacing it with another power supply
(see the
"Replacing a DC Power Supply Unit During Operations" section on page 10-9
into the same DC source. If the Input and Output LEDs turn green on the replacement power supply unit, contact TAC
(see the
Contacting Customer Service, on page
If you cannot determine the problem with the power supply or determine which power supply unit has the problem,
contact TAC.

Troubleshooting an HVAC/HVDC Power Supply Unit

The following conditions indicate that you need to troubleshoot an HVAC/HVDC power supply unit:
• The PSU LED on the chassis is amber.
• The Input or Output LED on the power supply unit is not green.
• The Fault LED on the power supply unit is flashing red.
Also, when there are power problems with other modules or the supervisor module PWR MGMT LED is
amber, you need to troubleshoot the power supply unit or check the seating of the modules that are not receiving
power.
For a listing of the power supply unit LEDs and the conditions that they indicate, see
.
To troubleshoot a power supply problem, follow these steps:
SUMMARY STEPS
1. Check to see if the Input and Output LEDs are lit.
2. If the Input LED is not lit, perform each of the following checks on the power cord used for the power
supply unit:
3. If the Output LED is not lit, verify that the power switch is turned on (1).
4. Make sure that the power supply unit is properly seated in the power supply bay.
5. Verify that the power supply unit is functional by replacing it with another power supply and plugging
its power cords into the same power source.
DETAILED STEPS
Step 1
Check to see if the Input and Output LEDs are lit.
Step 2
If the Input LED is not lit, perform each of the following checks on the power cord used for the power supply unit:
• Make sure that the power cord is securely connected to the power source.
• Turn the power supply switch to standby to 0 and then disconnect the power cord from the power source and reconnect
with another power source. After you connect to the power source, turn the power switch on (1).
Step 3
If the Output LED is not lit, verify that the power switch is turned on (1).
Step 4
Make sure that the power supply unit is properly seated in the power supply bay.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
132
136) to replace the defective power supply unit.
Troubleshooting
) and plugging its power cords
Table D-6 on page D-6