Chassis Airflow
• The Cisco Nexus 7004 switch uses side-to-back airflow to cool its modules and front-to-back airflow to
cool its power supplies as shown in
This switch requires right-side clearance for airflow into the chassis.
• The Cisco Nexus 7009 switch uses side-to-side airflow to cool its modules and front-to-back airflow to
cool its power supplies as shown in
This switch requires right- and left-side clearance for airflow into and out of the chassis.
• The Cisco Nexus 7010 switch uses front-to-back airflow as shown in
Nexus 7010 Chassis, on page
• The Cisco Nexus 7018 switch uses side-to-side airflow to cool its modules and front-to-back airflow to
cool its power supply units as shown in
204. This switch requires right- and left-side clearance for airflow into and out of the chassis.
Figure 140: Airflow for the Cisco Nexus 7004 Chassis
1
Right side-to-rear airflow for cooling supervisor
and I/O modules
2
Front-to-rear airflow for cooling power supplies
Figure 141: Airflow for the Cisco Nexus 7009 Chassis
need to insert 330517.jpg. this image is found in WEM and not in Astoria.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
202
Figure 140: Airflow for the Cisco Nexus 7004 Chassis, on page
Figure 141: Airflow for the Cisco Nexus 7009 Chassis, on page
203.
Figure 143: Airflow for the Cisco Nexus 7018 Chassis, on page
3
Exhaust out the rear to the hot aisle
Technical Specifications