Combustion Parameters; Technical Data - Immergas MINI EOLO X 24 3 E Instructions And Warnings

Hide thumbs Also See for MINI EOLO X 24 3 E:
Table of Contents

Advertisement

4.2

COMBUSTION PARAMETERS.

Gas nozzle diameter
Supply pressure
Flue flow rate at nominal heat output
Flue flow rate at min heat output
CO
at Nom Q./Min.
2
CO with 0% O
at Nom Q /Min.
2
NO
with 0% O
at Nom Q /Min.
X
2
Flue temperature at nominal output
Flue temperature at minimum output
4.3

TECHNICAL DATA.

Electrical connection
Nominal absorption
Installed electric output
Fan power consumption
Equipment electrical system protection
Ambient operating temperature range
Maximum flue overheating temperature
NO
X class
Weighted NO
X
Weighted CO
Type of appliance
Category
- The max. sound level emitted during boiler operation is < 55dBA.
The sound level value is referred to semianechoic chamber tests
with boiler operating at max. heat output, with extension of flue
gas exhaust system according to product standards.
- The weighted NO
value refer to the net calorific value.
x
48
G20
mm
1.35
mbar (mm H
O)
20 (204)
2
kg/h
55
kg/h
45
%
6.65 / 2.50
ppm
92 / 80
mg/kWh
180 / 140
°C
101
°C
94
V/Hz
A
W
W
-
°C
°C
-
mg/kWh
mg/kWh
C12 /C32 / C42 / C52 / C62 / C82 / B22 / B32
G30
G31
0.79
0.79
29 (296)
37 (377)
55
56
43
42
7.70 / 3.00
7.50 / 3.10
137 / 95
90 / 80
260 / 160
240 / 160
103
101
96
99
230/50
0.66
130
35.0
IPX5D
0 ÷ 40
180
3
138
95
II2H3P

Advertisement

Table of Contents
loading

Table of Contents