3.14 CASING REMOVAL.
To facilitate boiler maintenance and to access
the control panel, the casing can be completely
removed as follows:
- remove the intake / exhaust terminal (1);
- loosen the two screws (2);
- remove the front (3) of the boiler by pushing it
upwards and at the same time pull it towards
yourself to release it from the upper pins (4);
1
14
2
- remove the lower protection plate (5) by loo-
sening the two screws (6);
- remove the upper / right bracket (7) by loo-
sening the upper screw (8) and pushing it to
remove it from the screw with stop (9);
- remove the casing side (10) by loosening the
screws (11) and pulling it towards yourself to
free the side from the seat (12) (Fig. 3-5);
4
11
13
2
4
11
10
3
11
5
6
23
8
7
9
A
A
Part. A
12
3-5