Fv100-T Indicators; Model Codes; Pressure Drop Data; Cabling - Omega Vortex FV100 Series User Manual

Shedding flowmeter & temperature
Table of Contents

Advertisement

FV100-T LED Indicators
The LED's adjacent to the engineering units of GPM, LPM, F, & C have two functions. The first is to
indicate the process variable being displayed and its respective engineering unit, the second to indicate
alarm conditions. If temperature is being displayed, say 75 F, then 75 will appear in the display and the
LED adjacent to F will be lit. If the temperature would increase to its respective set point, then the actual
value will be displayed, the F LED will remain lit and the LED adjacent to C would begin flashing. If, at
the same time, there is a low flow condition, both LED's next to GPM & LPM will also flash - indicat-
ing a flow fault also, so that you can press the MENU button to verify the flow rate.
In either case, if flow or temperature is the displayed value, when a fault condition occurs on the
nondisplayed value, the two indicator LED's associated with that variable will both flash to provide
a local indication of a fault. The solid state relays will still function independently, also regardless of the
variable being displayed. As will the 4-20 mA outputs.

MODEL CODES

MODEL CODE SELECTION
Code
Flow
Only
FV103
x
FV103-T
FV104
x
FV104-T
FV105
x
FV105-T
FV106
x
FV106-T
PRESSURE DROP CHARTS
12
10
8
5
2
1
.5
.2
.1
.05
.3
.6 1 2
5 10
25
100
15
50
FLOW (GPM)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Flow and
Pipe Size
Temperature
in Inches
3/4
x
3/4
x
1 1/2
x
1 1/2
x
1000
750
500
350
200
100
50
35
20
10
5
3.5
10 20
250
2
5
50
30
100
200 300
FLOW (LPM)
GPM
Min
Max
2.5
2.5
1
5
1
5
10
10
2
20
2
20
CABLING AVAILABLE with METERS
Series
Description Length in
FV100
FV100-T
200 600 1200
300 800
11
Flow Range
LPM
Min
25
9
25
9
50
20
50
20
100
40
100
40
200
75
200
75
Meters
5 pin
1
female
3
10
8 pin
1
female
3
10
Max
95
95
190
190
380
380
750
750
Part
Number
FV100-C1
FV100-C2
FV100-C3
FV100-CT1
FV100-CT2
FV100-CT3

Advertisement