PairGain HiGain HLU-319 Manual page 37

Line unit
Hide thumbs Also See for HiGain HLU-319:
Table of Contents

Advertisement

150-319-142-01
If a loopback is in effect, the 30 second time-out does not occur. The
active loopback session continues until the loopback times out in
accordance with the LBTO setting.
Only the SMJK loopback can exist with other networks at any given
time.
When a loopback is active, pressing both buttons for three seconds
terminates the loopback, ends the manual loopback session, and returns
the front panel display to the normal mode.
To initiate a manual loopback session:
1
Simultaneously press the MODE and SEL buttons for at least three
seconds. The following message appears on the front panel display:
MAN LPBK
followed by the message:
NLO
2
Do one of the following:
To execute an NLOC loopback, press the SEL button. The message
changes from NLO to NLOC.
To execute an NREM loopback:
To execute a CREM loopback, press the MODE button again.
To execute a CLOC loopback, press the MODE button a third time.
Note that these same loopbacks can be initiated from the Craft (RS-232) port
by choosing the Option D, Loopback Mode, on the Main Menu.
All loopbacks, except the SMJK loopback, are initiated by in-band
commands in the T1 payload or by a command from the HLU-319 List 4B
(front panel buttons or maintenance screen selections). Initiate loopbacks
using HG for the HLU-319 List 4B or PL for T1 payload on the Loopback
Menu and Span Status screen.
HLU-319 List 4B
December 22, 1997
Press the MODE button. The message changes from NLO to
NRE.
Press the SEL button to execute the NREM loopback.
PairGain Engineering - Plant Series
Revision 01
31