Page 1
Model List Number Part Number HLU-319 150-1140-42 ECHNOLOGIES NGINEERING ERVICES ECHNICAL RACTICE 150-319-142-01 ECTION Revision History of This Practice Revision 01—December 22, 1997 A) Initial Release...
Page 3
SING ANUAL Two types of messages, identified by icons, appear in the text. Notes contain information about special circumstances. Cautions indicate the possibility of equipment damage or the possibility of personal injury. HLU-319 List 4B PairGain Engineering - Plant Series...
Page 4
Revision 01 December 22, 1997 150-319-142-01 PairGain Engineering - Plant Series HLU-319 List 4B...
Set Clock ..............15 System Settings ............16 Select Loopback Test ..........17 View Performance Data .......... 18 View Performance History ........19 View Alarm History ..........20 Enter Circuit ID Number ......... 20 HLU-319 List 4B PairGain Engineering - Plant Series...
Page 6
HiGain Terms___________________________________________40 Front Panel Messages ____________________________________41 Certification and Warranty _______________________________45 VCCI Certification ..............45 UL Listing ................45 Warranty ................. 46 Technical Support _______________________________________47 Phone or Fax................47 Returns..................47 World Wide Web..............48 PairGain Engineering - Plant Series HLU-319 List 4B...
784 kbps full duplex 2B1Q HDSL transmission on two pairs • Front panel status indicating LED • On/off front panel display power cycling • DSX-1 LOS detector (125 consecutive zeros) • Margin threshold alarm • HDSL AIS and SmartJack AIS options HLU-319 List 4B PairGain Engineering - Plant Series...
800 ohms. Table 1. HDSL Loss over Cables Loss at 196 kHz Cable Gauge Ohms per km (db/km) 0.4 mm 12.7 272.3 0.51 mm 170.6 0.61 mm 0.91 mm 52.5 PairGain Engineering - Plant Series HLU-319 List 4B...
Margin Indicator Displays HDSL loop SNR margin for each HDSL loop relative to 10 BER operation Electrical Protection Secondary surge protection on DS1 and HDSL ports; Power cross protection on HDSL ports HLU-319 List 4B PairGain Engineering - Plant Series...
HLU-319 List 4B and the HRU-412 List 8B. This provides a total capacity of 1.568 Mbps between the two units. The HiGain HLU-319 List 4B receives a 1.544 Mbps DS1 data stream from the DSX-1 digital cross connect interface. The HLU-319 List 4B contains a DSX-1 frame synchronizer controlled by an 8-bit microprocessor that determines the type of framing on the DS1 stream and synchronizes to it.
Page 11
The HLU-319 List 4B contains a main power supply that converts -48 Vdc power to voltage for the HLU-319 List 4B circuitry. The female 9-pin (DB-9) Craft (RS-232) port, on the front panel, provides access to HiGain system configuration, provisioning, and performance monitoring. HLU-319 List 4B PairGain Engineering - Plant Series...
The MAL alarms (8 and 9, above) are disabled by setting the margin alarm threshold to 0 (on the Systems Settings menu). A minor alarm can be retired by executing the Alarm CutOff (ACO) option by pressing the SEL button on PairGain Engineering - Plant Series HLU-319 List 4B...
Page 13
-80 V. It can sink a current of 10 mA. Pin 7 is the NMA serial bus. It allows access to the HMU-319 List 5B, which provides shelf management. HLU-319 List 4B PairGain Engineering - Plant Series...
December 22, 1997 150-319-142-01 Front Panel Features Figure 1 shows the front panel of the HLU-319 List 4B. Table 2 describes the front panel components. Figure 1. HLU-319 List 4B Front Panel Components PairGain Engineering - Plant Series HLU-319 List 4B...
Page 15
Card handle Pulls down to release the HLU-319 List 4B from the shelf slot. The handle closes when the HLU-319 List 4B is properly installed in a slot. HLU-319 List 4B PairGain Engineering - Plant Series...
The HLU-319 List 4B mounts in wire-wrapped and connectorized shelves, including: • PairGain HMS-318 (22 slot, 19 inch shelf) • PairGain HMS-319 (3 slot, 19 inch horizontal shelf) • PairGain HMS-317 (28 slot, 23 inch shelf) • PairGain HMS-308 (8 slot remote enclosure)
Page 17
Place your thumbs on the HLU-319 List 4B front panel and push the HLU-319 List 4B into the card-edge connector until it is entirely within the card guides. HLU-319 List 4B PairGain Engineering - Plant Series...
Figure 3 for the DB-9 female connector wiring. Figure 3. HLU-319 List 4B Craft Port Wiring Connect the other end of the terminal cable to the console port on the dumb terminal. PairGain Engineering - Plant Series HLU-319 List 4B...
NONE E. VIEW PERFORMANCE DATA F. VIEW PERFORMANCE HISTORY G. VIEW ALARM HISTORY H. ENTER CIRCUIT ID # Access options on the Main Menu by typing the letter of the desired option. HLU-319 List 4B PairGain Engineering - Plant Series...
B8ZS (E)xit (C)lear (U)pdate Type to update the Span Status screen to the latest information. Type & to clear the Span Status screen data. Type to exit to the Span Status screen. PairGain Engineering - Plant Series HLU-319 List 4B...
Type the at the Update Remote? prompt to update the HRU-412 List 8B clock. SET CLOCK TIME: 00:01:39 DATE: 04/09/98 CIRCUIT ID#: Format: HH:MM MM/DD/YY NEW TIME: 12:00 NEW DATE: 04/14/98 (U)PDATE REMOTE? HLU-319 List 4B PairGain Engineering - Plant Series...
Setting Options” on page 23 Table 3 on page 24 for more information about the options. When all selections are made, type to exit the option. & Type to confirm the changes. PairGain Engineering - Plant Series HLU-319 List 4B...
B. NETWORK LOOP HLU (NLOC) C. NETWORK LOOP HRU (NREM) G. CUSTOMER LOOP HLU (CREM) H. CUSTOMER LOOP HRU (CLOC) (E)xit Type the number of the desired loopback option. Type to exit the Loopback Menu. HLU-319 List 4B PairGain Engineering - Plant Series...
000/000 000/000 000/000 000/000 000/000 000/000 (E)xit (P)revious (N)ext Type to view the previous Performance Data screen. Type to view the next Performance Data screen. Type to exit the Performance Data screens. PairGain Engineering - Plant Series HLU-319 List 4B...
04/09/98-00:00 04/09/98-00:00 MARGIN L2 LAST CLEARED: NONE (E)xit (C)lear (U)pdate Type to exit the Alarm History screen. Enter Circuit ID Number From the Main Menu, type to enter a circuit identification number. PairGain Engineering - Plant Series HLU-319 List 4B...
30 seconds.) • Accept the requested parameter changes by pressing the SEL button. Yes displays and the changes are made. The display returns to its normal mode. HLU-319 List 4B PairGain Engineering - Plant Series...
T1 directions, the HiGain T1 output codes will not match, causing the received data to be AMI instead of B8ZS (or vice versa), and thus violating the 1s density rules by having excessive zeroes. PairGain Engineering - Plant Series HLU-319 List 4B...
AMI mode, it can receive B8ZS but can only transmit AMI. The Self-test mode, which occurs when both HDSL loops are out of sync, causes the Alarm Indicating Signal (AIS) pattern to exhibit occasional BPVs. HLU-319 List 4B PairGain Engineering - Plant Series...
Page 30
Sets the equalizer to DSX-1 for 81 m to 121 m. Sets the equalizer to DSX-1 for 122 m to 162 m. Sets the equalizer to DSX-1 for 163 m to 200 m. * Indicates HLU-319 List 4B factory (default) settings. (Continued) PairGain Engineering - Plant Series HLU-319 List 4B...
Page 31
HDSL loop or a total of 170 BPVs on DSX-1) occur within a 24 hour period. NONE* Prevents generation of a minor alarm due to excessive errored seconds. * Indicates HLU-319 List 4B factory (default) settings. (Continued) HLU-319 List 4B PairGain Engineering - Plant Series...
Page 32
Places both the HLU-319 List 4B and HRU-412 List 8B into their B8ZS modes. Places both the HLU-319 List 4B and HRU-412 List 8B into their AMI modes. * Indicates HLU-319 List 4B factory (default) settings. (Continued) PairGain Engineering - Plant Series HLU-319 List 4B...
Page 33
Threshold determines the minimum allowable margin below which a minor alarm can occur. Note that setting the threshold to 0 inhibits the margin alarm. 4 dB* * Indicates HLU-319 List 4B factory (default) settings. (Continued) HLU-319 List 4B PairGain Engineering - Plant Series...
(-42.5 V). It determines the shelf fusing requirements. Heat baffles should be placed between every shelf to deflects the rack’s heat outward and reduces thermo stress on the plugs. PairGain Engineering - Plant Series HLU-319 List 4B...
These additions make A1LB identical to A2LB. A1LB is given a separate identity to allow future T1E1 enhancements without affecting A2LB. Addressable Repeater Loopback Functions A HiGain system is capable of five special in-band loopback (SPLB) command sequences. HLU-319 List 4B PairGain Engineering - Plant Series...
If the MODE or SEL button is not pressed for 30 seconds and no loopback is in effect, the manual loopback session terminates and the the front panel display returns to normal mode. PairGain Engineering - Plant Series HLU-319 List 4B...
Page 37
T1 payload or by a command from the HLU-319 List 4B (front panel buttons or maintenance screen selections). Initiate loopbacks using HG for the HLU-319 List 4B or PL for T1 payload on the Loopback Menu and Span Status screen. HLU-319 List 4B PairGain Engineering - Plant Series...
All equalizers should be set to the distance from the DSX-1 to the shelf. The transmit and receive T1 DSX-1 ports have splitting access and bridging miniature 210 series jacks. Connecting one cable between the two bridging PairGain Engineering - Plant Series HLU-319 List 4B...
LED on the front panel display and on the Span Status screen.) Repeat step 2. If the test passes, the problem is in the downstream direction. If it fails, the problem is in the upstream (CO) direction. HLU-319 List 4B PairGain Engineering - Plant Series...
This error pattern repeats every 20 seconds as long as the IOR loopback pattern is being sent. This same 20 second repeat scenario also applies to ILR, Time-out Override, and Query commands. PairGain Engineering - Plant Series HLU-319 List 4B...
Page 41
To avoid this uncertainty, PairGain recommends sending the IR commands unframed. The HLU-319 List 4B is now in Logic Loopback. The Loopback Time-out option is user settable to: •...
Page 42
ILR-2 LPBK (NREM HRU Loop up 1101(D)0101(5)1101(D)0101(5) and CLOC 20 bit errors) IR LPDN Loopdown (HLU 1001(9)0011(3)1001(9)0011(3) or HRU) IR QUERY LPBK Query loopback 1101(D)0101(5)1101(D)0101(5) IR ALTERNATE QUERY Alternate Query 1101(D)0101(5)1110(E)1010(A) LPBK loopback (Continued) PairGain Engineering - Plant Series HLU-319 List 4B...
Page 43
20 bit errors each, including frame bits. Those test sets that do not count frame error bits as data bit errors will indicate fewer bits than the HRU transmits for this CI loopback. HLU-319 List 4B PairGain Engineering - Plant Series...
• LU = LoopUp • LD = LoopDown • NI = Network Interface • CI = Customer Interface • ESF-DL = Extended Super Frame-Data Link PairGain Engineering - Plant Series HLU-319 List 4B...
Page 45
Bit Error Ratio (BER) on the facility. Note that the entire arming and loopback sequence can be initiated at the remote HRU location. ** The number in ( ) identifies the HEX number for the 4-bit group. HLU-319 List 4B PairGain Engineering - Plant Series...
The number of seconds during which the T1 input signal was absent (125 or more consecutive 0s). Frame Type Type of T1 framing input stream (SF, ESF, Unframed or No Activity). (Continued) PairGain Engineering - Plant Series HLU-319 List 4B...
HRU-412 List 8B. NREM Network Remote Loopback DSX-1 signal is looped back to DSX-1 at HRU-412 List 8B. SMJK Remote SmartJack Loopback DSX-1 signal is looped back to DSX-1 at HRU-412 List 8B. (Continued) HLU-319 List 4B PairGain Engineering - Plant Series...
Page 48
Armed and ready to respond to Intelligent Repeater loop codes. Alarm CutOff A minor alarm occurred and was retired to an ACO condition, after pressing the SEL button on the HLU-319 List 4B front panel. (Continued) PairGain Engineering - Plant Series HLU-319 List 4B...
Page 49
HLU-319 List 4B List number Displayed during System Settings review mode. Frame: SF, ESF, UNFR, None Defines the type of frame pattern being received from the DSX-1. Displayed during System Settings review mode. (Continued) HLU-319 List 4B PairGain Engineering - Plant Series...
Page 50
MNGD Managed The HLU-319 List 4B is under control of the HMU-319 List 5B network management unit. In this state, the Craft port on the HLU-319 List 4B front panel is inoperative. PairGain Engineering - Plant Series HLU-319 List 4B...
Always disconnect telephone lines and power connections from wall outlets before servicing or disassembling this equipment. All wiring external to the product should follow the provisions of the current edition of the National Electrical Code. HLU-319 List 4B PairGain Engineering - Plant Series...
PairGain's sole opinion, is determined to be defective upon examination at our plant. The transportation charges from the Buyer to PairGain will be prepaid by the Buyer. When the equipment is shipped back to the Buyer, PairGain will pay the charges, unless no trouble is found (NTF), in which case the buyer will pay for the shipment.
PairGain provides technical support by phone, fax, and the World Wide Web. Phone or Fax PairGain Technical Assistance is available 24 hours a day, 7 days a week by contacting PairGain’s Customer Service Engineering group at one of the following numbers: •...
A description of the equipment, as well as the number of units that you are returning. Be sure to include the model and part number of each unit. • The shipping address to which PairGain should return the repaired equipment. • The reason for the return: a) The equipment needs an ECO/ECN upgrade.
Page 56
Corporate Office 14402 Franklin Avenue Tustin, CA 92780 Tel: (714) 832-9922 Fax: (714) 832-9924 For Technical Assistance: (800) 638-0031...