150-319-142-01
Table 3. HLU-319 List 4B System Setting Menu Options (Continued)
Option Parameter
L
DIS
ENA*
S
GNLB*
(S
A1LB and A2LB
cont)
A3LB
A4LB
A5LB
P
DIS
ENA*
Z
ON
OFF*
R
17
170
NONE*
* Indicates HLU-319 List 4B factory (default) settings. (Continued)
HLU-319 List 4B
December 22, 1997
Description
Configures the HiGain system to ignore the (2-in-5) in-band
SmartJack loopback command.
Enables the HiGain system to recognize the (2-in-5) in-band
SmartJack loopback command.
Configures the HiGain system to respond to the generic
(3/4/5/6-in-7) in-band loopback codes.
Configures the HiGain system to respond to the Teltrend
addressable repeater in-band loopback codes.
Configures the HiGain system to respond to the Wescom
addressable repeater in-band loopback codes.
Configures the HiGain system to respond to the Wescom
Mod 1 addressable repeater in-band loopback codes.
Configures the HiGain system to respond to the Teltrend
Mod 1 addressable repeater in-band loopback codes.
Disables powering to the HRU-412 List 8B and doubler.
Enables powering to the HRU-412 List 8B and doubler.
Tells the HiGain system that the ESF frame is operating in its
Zero Byte Time Slot Interface (ZBTSI) mode.
Tells the HiGain system that the ESF frame is operating in its
normal non-ZBTSI mode.
Flashes the red Status LED when 17 Errored Seconds (ES)
(17 HDSL cyclic redundancy check (CRC) errors on either
HDSL loop or a total of 17 BPVs on DSX-1) occur within a
24 hour period.
Flashes the red Status LED when 170 ES (170 HDSL CRC
errors on either HDSL loop or a total of 170 BPVs on DSX-1)
occur within a 24 hour period.
Prevents generation of a minor alarm due to excessive
errored seconds.
PairGain Engineering - Plant Series
Revision 01
25