Test Procedure - New Leader L5034 G4 Assembly/Operators/Parts Manual

Hide thumbs Also See for L5034 G4:
Table of Contents

Advertisement

Spread Pattern

Test Procedure

Using the data sheets supplied with the kit, document all spreader information and adjustments as
necessary� See Figure 1�
1
NLM
Site:
10/07/2016
Date:
MAP
Material Name:
65
Density:
6
Crush Strength:
324
SGN:
320
Spinner Speed:
7
Select an area for testing measuring at least 120 feet x 200 feet (37 m x 61 m), and with a slope of less than
two degrees�
All testing should be done when the wind velocity is less than 5 MPH (8�05 km)� If wind is present, testing
must be done with spreader traveling parallel (within ± 15 degrees) to the wind direction�
Do not allow loaded spreader to sit for more than one hour prior to testing�
At this stage of testing, drive the spreader over the collection trays in ONLY ONE DIRECTION�
Insert a plastic grid into each of the 23 collection trays� Position the blue collection tray in the center of the
spreader's path with the longest dimension of the tray parallel to the direction of travel. Position the first
left-hand and right-hand trays 10' (3m) from center, and all subsequent trays on 5' (1�5m) centers�
www.NewLeader.com
(800) 363-1771
SPREAD PATTERN DATA SHEET
New Leader Manufacturing
Rev.
Spreader Model:
Serial No.
10am
Time:
Conveyor Type:
Feedgate Height:
CFR/Constant:
lbs/acre
780
Controller Vehicle Speed:
RPM
L4000G4
432165
#4 BOC
3.25
in.
3"
in.
1-2-1-2
Wind: From
.232
Temperature:
12
Controller Swath Width:
MPH
Figure 1
- 91 -
L5034G4
1330 76th Ave SW
Cedar Rapids, IA 52404-7052
(319) 363-8281
Straight
at
MPH
5
41%
%
67
°F
90
7
6
305438-J

Advertisement

Table of Contents
loading

Table of Contents