CyberPower CPS825AVR User Manual page 12

With usb interface and powerpanel plus software

Advertisement

DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power
Wiring
On
Fault
On
Off
Off
On/Off
Off
On/Off
Off
Off
On/Off
On/Off
Off
Off
On/Off
On
APPROXIMATE RUNTIME IN MINUTES
Load
(Watts)
75
125
150
200
250
300
350
410
Circuit
Alarm
Breaker
Set
Two
Set
Beeps
Rapid
Set
Beeps
Two
beeps or
Up
rapid
beeps
Long
Set
Beep
Long
Up
Beep
Set/Up
None
CPS825AVR Model
Runtime
50
35
25
15
10
5
4
3
Off
Utility Failure- The UPS is providing battery power to
the Battery-Power Supplied outlets.
Utility Failure- The UPS is providing battery power.
The rapid beeps indicate the battery will run out of
Overload- Occurs in the Full-time Surge Protection
Outlets. Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5 seconds,
reset the circuit breaker and turn the UPS on.
Overload- Occurs in the Battery-power Supplied
Outlets. Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5 seconds,
reset the circuit breaker and turn the UPS on.
Overload- Occurs in the Battery-power Supplied
Outlets. Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5 seconds,
reset the circuit breaker and turn the UPS on.
Electrical Wiring Fault- This indicates a wiring a
problem such as a bad ground, missed ground or
reversed wiring within the AC outlet. User is advised
to disconnect all electrical equipment from the outlet
and have the outlet checked by an electrician.
Sample Systems
Desktop PC with 15" Monitor
Desktop PC with 17" Monitor
Desktop PC with 21" Monitor
Condition
Normal
charge within a few minutes.
45-60
30-45
25-30