Battery Charge Indication

The status of the battery charge is indicated as follows.
When Printer is On
Power
Error
Charge
LED
LED
LED
O
N
O
O
N
N
O
N
k
O
O
k
• Battery charging should be performed under ambient temperatures within the guaranteed operating range of
0 to 40°C (32 to 104°F).
• Charging will stop if the ambient temperature is outside the chargeable temperature range (below 0°C or
above 40°C).
• When charging in an environment of 35°C or higher, the charging time may be extended because the internal
temperature rise is detected and charging is stopped and started repeatedly.
• If the battery is not fully charged after approximately 5 hours of charging, it is assumed that the battery is
faulty and the Charge LED will flash. The battery cannot be used and should be replaced with another
battery.

Network Connection Status (Wi-Fi model)

Wi-Fi LED
The printer is connected to Wi-Fi and ready for communication.
O
The printer is temporarily unable to communicate, such as when it is obtaining an IP address
k
after being connected to Wi-Fi.
Not connected to a network
N
The LED flashing pattern is: lighting for 320 ms followed by a pause for 320 ms.
When Printer is Off
Power
Error
Charge
LED
LED
LED
N
N
O
N
N
N
N
N
k
Chapter 1 Product Overview
O: ON k: Flashing N: OFF
Battery status
Charging (0-40°C)
The battery is fully charged or does not need to be
charged
Outside the chargeable temperature range:
-20 (not including -20) to less than 0°C, or 40 (not
including 40) to less than 55°C
Battery high temperature error (55°C or higher)
Battery low temperature error (-20°C or lower)
Battery failure
O: ON k: Flashing N: OFF
Printer status