Page 1
Instructions for Use Color LCD Monitor Important Please make sure you read the Instructions for Use and Installation Manual before use. Please retain this manual for future reference. • See the Installation Manual for monitor settings and adjustments. • The latest product information, including the Instructions for Use, is available on our web site.
Page 2
EIZO Corporation. EIZO Corporation is under no obligation to hold any submitted material or information confidential unless prior arrangements are made pursuant to EIZO Corporation’s receipt of said information.
PRECAUTIONS PRECAUTIONS Important This product has been adjusted specifically for use in the region to which it was originally shipped. If operated outside this region, the product may not perform as stated in the specifications. To personal safety and proper maintenance, please read carefully the "PRECAUTIONS" section and the caution statements on the monitor.
Page 4
PRECAUTIONS Symbol This symbol indicates Caution: Federal law (USA) restricts this device to sale by or on the order of a licensed healthcare practitioner. Medical device in the EU Importer in the EU Mark signifying compliance with UK regulations UK Responsible Person Authorised representative in Switzerland...
Page 5
A unit placed on an inadequate surface may fall and result in injury. If the unit falls, disconnect the power immediately and ask your local EIZO representative for advice. Do not continue using a damaged unit. Using a damaged unit may result in fire or electrical shock.
Page 6
PRECAUTIONS WARNING Use the unit in an appropriate location. Otherwise, fire, electrical shock, or equipment damage may result. • Do not place outdoors. • Do not place in any form of transportation (ships, aircraft, trains, automobiles, etc.). • Do not place in dusty or humid environments. •...
Page 7
Before installation, make sure that desks, walls, or any other installation surface has adequate mechanical strength. If the unit falls, disconnect the power immediately and ask your local EIZO representative for advice. Do not continue using a damaged unit. Using a damaged unit may result in fire or electrical shock.
Page 8
PRECAUTIONS CAUTION CAUTION Check the operational state before use. Begin use after ensuring that there are no problems with the displayed image. When using multiple units, begin use after ensuring that the images are displayed appropriately. CAUTION Securely fix cables / cords that have a fixing feature. If they are not fixed securely, cables / cords may disconnect, and subsequently images may be cut off and your operations may be disrupted.
Page 9
PRECAUTIONS CAUTION Do not touch the power plug with wet hands. Touching them may result in electrical shock. CAUTION Do not place any objects around the power plug. This is to facilitate disconnecting the power plug in case of a problem to avoid fire or electrical shock.
• The specifications noted in this manual are only applicable when using the power cords provided together with the product and EIZO-specified signal cables. • Only use EIZO accessories products specified by EIZO with this product. Precautions for Use • Parts (such as the LCD panel and the fan) may deteriorate if used over extended periods of time.
• To adjust measurement results of the integrated calibration sensor (Integrated Front Sensor) to those of an EIZO external sensor (UX2 sensor) that is sold separately, perform correlation between the Integrated Front Sensor and the external sensor using RadiCS / RadiCS LE.
• Look at the screen from a proper distance and from a proper angle. Cybersecurity Warnings and Responsibilities • Firmware update should be performed through EIZO Corporation or its distributor. • If EIZO Corporation or its distributor instructs to update the firmware, update it immediately.
1.1.5 Space-saving design................16 1.1.6 Monitor operation from the mouse and keyboard ........16 Package Contents....................17 1.2.1 EIZO LCD Utility Disk................17 1.2.2 RadiCS LE ....................17 1.2.3 To use RadiCS LE .................. 18 Controls and Functions ..................19 1.3.1...
Page 14
CONTENTS 4.1.2 LCD Panel....................28 4.1.3 Video Signals ..................28 4.1.4 USB......................29 4.1.5 Power...................... 29 4.1.6 Physical Specifications ................29 4.1.7 Operating Environmental Requirements..........29 4.1.8 Transport / Storage Conditions ............... 30 Compatible Resolutions ..................30 Accessories......................30 Appendix ........................31 Medical Standard ....................
Introduction | 1 1 Introduction Thank you very much for choosing an EIZO color LCD monitor. 1.1 Features 1.1.1 Hybrid monochrome and color display When the Hybrid Gamma PXL function is enabled, this product automatically differentiates between monochrome and color parts of the same image at a pixel level and displays them respectively in optimal gradients.
1 | Introduction 1.1.4 Equipped with USB Type-C® quick-charge function This allows you to recharge your smartphone or tablet in a short period of time. Power supply Max. 15 W (5 V/3 A) 100% 1.1.5 Space-saving design The monitor has two USB upstream ports. You can operate two PCs using one set of USB devices (mouse, keyboard, etc.).
1.2 Package Contents Check that all of the following items are contained in the package. If any of these are missing or damaged, contact your dealer or local EIZO representative. Note • It is recommended that the box and packing materials be stored so that they can be used to move or transport this product.
1 | Introduction Monitor operations • Switching CAL Switch modes • Switching input signals • Function that assigns any CAL Switch mode to a part of the screen and displays an image (Point-and-Focus) • Switching PCs that use USB devices (Switch-and-Go) • Entering power saving mode (Backlight Saver) •...
Introduction | 1 1.3 Controls and Functions 1.3.1 Front Approx. 30° 1. Integrated Front Sensor This sensor is used to perform calibration and Grayscale Check. (Movable) 2. Illuminance Sensor This sensor measures environmental illumination. Environmental illumination measurement is performed using the RadiCS / RadiCS LE quality control software.
1 | Introduction 1.3.2 Back 1. Handle This handle is used for transportation. Attention • Firmly hold the monitor by the handle and the bottom while carrying it, and do not put pressure on the LCD panel or drop the monitor. Do not hold the sensor section on the front side of the monitor.
Installation / Connection | 2 2 Installation / Connection 2.1 Before installation Carefully read PRECAUTIONS [} 3] and always follow the instructions. If you place this product on a lacquer-coated desk, the color may adhere to the bottom of the stand due to the composition of the rubber. Check the desk surface before use. 2.1.1 Installation conditions When installing the monitor in a rack, ensure that there is adequate space around the sides, back and top of the monitor.
2 | Installation / Connection 2.2 Connecting Cables Attention • Check that the monitor, PC, and peripherals are powered off. • When replacing the current monitor with this monitor, see 4.2 Compatible Resolutions [} 30] change the PC settings for resolution and vertical scan frequency to those that are available for this monitor, before connecting the PC.
Page 23
Installation / Connection | 2 Attention • Visit the EIZO web site for information about monitors and graphics boards that can be used for the daisy-chain connection: (www.eizoglobal.com) • When using a daisy-chain connection, connect the cable to the input connector • To set up a daisy-chain connection, you need to select "DisplayPort 1" to "Version 1.2" on the Administrator Settings menu.
2 | Installation / Connection Note • Switching between PCs that use USB devices can be performed by connecting two PCs to two monitors as in the following figure. For details on how to switch PCs that use USB devices, refer to the Installation Manual (on the CD-ROM). 2.3 Turning On the Power 1.
Installation / Connection | 2 2.4 Adjusting the Screen Height and Angle Hold the top and bottom or left and right edges of the monitor with both hands, and adjust the screen height, tilt and swivel the screen to the optimum position for performing tasks. Attention •...
• Turn off the main power, and then turn it on again. Power switch indicator blinks: Orange, Green • Connect via the signal cable specified by EIZO. Turn off the main power, and then turn it on again. • If the signal cable is connected to DisplayPort 1 ( ), try switching the DisplayPort version.
Page 27
No-Picture Problem | 3 • Check whether the signal cable is connected properly. Is the signal cable connected to for inputting the DisplayPort signal? is used for output when a daisy-chain connection is set up. • Turn off the main power, and then turn it on again. The message "Signal Error"...
4 | Specifications 4 Specifications 4.1 List of Specifications 4.1.1 Type RX270 Anti-Glare RX270-AR Anti-Reflection 4.1.2 LCD Panel Type Color (IPS) Backlight Size 21.3" (54.0 cm) Resolution 1200 dots x 1600 lines Display Size (H x V) 324.0 mm x 432.0 mm Pixel Pitch 0.270 mm x 0.270 mm Display Colors...
Specifications | 4 4.1.4 USB Port Upstream USB-B x 2 Downstream USB-A x 2 Charging Only USB-C® x 1 Standard USB Specification Revision 2.0 Supply Current Downstream (USB-A) Max. 500 mA per port Quick Charge Only (USB- Max. 15 W (5 V/3 A) For charging only.
Appendix Appendix Medical Standard • It shall be assured that the final system is in compliance to IEC60601-1-1 requirement. • Power supplied equipment can emit electromagnetic waves, that could influence, limit or result in malfunction of the monitor. Install the equipment in a controlled environment, where such effects are avoided.
Appendix EMC Information The RadiForce series has a performance that appropriately displays images. Environments of Intended Use The RadiForce series is intended to be used in Professional healthcare facility environments such as clinics and hospitals. The following environments are not suitable for the RadiForce series to be used: •...
• Be sure to use the cables attached to the product, or cables specified by EIZO. Use of cables other than those specified or provided by EIZO of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and improper operation.
Page 34
Appendix Electromagnetic immunity The RadiForce series has been tested at the following compliance levels according to the testing requirements for professional healthcare facility environments specified in IEC / EN60601-1-2. The customer or the user of the RadiForce series should assure that it is used in such an environment.
Page 35
Appendix Immunity test Test level for Compliance level Electromagnetic environment - professional Guidance healthcare facility environments Portable and mobile RF communications equipment should be used no closer to any part of the RadiForce series, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Page 36
Appendix abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the RadiForce series. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Page 37
Appendix Recommended separation distances between portable or mobile RF communication equipment and the RadiForce series The RadiForce series is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the RadiForce series can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the RadiForce series.
Page 38
Appendix The RadiForce series is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. For other portable and mobile RF communication equipments (transmitters), minimum distance between portable and mobile RF communications equipment (transmitters) and the RadiForce series as recommended below, according to the maximum output power of the communications equipment.
Note Use the attached specified cable below or EIZO signal cable with this monitor so as to keep interference within the limits of a Class B digital device. • AC Cord •...
Appendix Declaration of compliance with India RoHS We, EIZO Corporation, hereby declare and guarantee that this product has been designed and manufactured in compliance with the E-Waste management rule 2016 which prohibit the inclusion of the following substances except for the exemptions listed in schedule II.