Page 1
Instructions for Use Color LCD Monitor Important Please make sure you read the Instructions for Use and Installation Manual before use. Please retain this manual for future reference. • See the Installation Manual for monitor settings and adjustments. • The latest product information, including the Instructions for Use, is available on our web site.
Page 2
EIZO Corporation. EIZO Corporation is under no obligation to hold any submitted material or information confidential unless prior arrangements are made pursuant to EIZO Corporation’s receipt of said information.
PRECAUTIONS PRECAUTIONS Important This product has been adjusted specifically for use in the region to which it was originally shipped. If operated outside this region, the product may not perform as stated in the specifications. To personal safety and proper maintenance, please read carefully the "PRECAUTIONS" section and the caution statements on the monitor.
Page 4
PRECAUTIONS Symbol This symbol indicates Importer in the EU Mark signifying compliance with UK regulations UK Responsible Person Authorised representative in Switzerland Authorised representative in the European Community...
A unit placed on an inadequate surface may fall and result in injury. If the unit falls, disconnect the power immediately and ask your local EIZO representative for advice. Do not continue using a damaged unit. Using a damaged unit may result in fire or electrical shock.
Page 6
PRECAUTIONS WARNING Use the unit in an appropriate location. Otherwise, fire, electrical shock, or equipment damage may result. • Do not place outdoors. • Do not place in any form of transportation (ships, aircraft, trains, automobiles, etc.). • Do not place in dusty or humid environments. •...
Page 7
Before installation, make sure that desks, walls, or any other installation surface has adequate mechanical strength. If the unit falls, disconnect the power immediately and ask your local EIZO representative for advice. Do not continue using a damaged unit. Using a damaged unit may result in fire or electrical shock.
PRECAUTIONS CAUTION CAUTION Do not look directly at the light source of the backlight or task light. It can potentially cause eye discomfort and vision problems. CAUTION Do not apply excessive force to the task light arm. Bending or twisting the arm with strong force may lead to damage or malfunction. CAUTION Check the operational state before use.
Page 9
PRECAUTIONS CAUTION Do not block the ventilation slots on the cabinet. • Do not place any objects on the ventilation slots. • Do not install the unit in a place with poor ventilation or inadequate space. • Do not use the unit laid down or upside down. Blocking the ventilation slots prevents proper airflow and may result in fire, electrical shock, or equipment damage.
• The specifications noted in this manual are only applicable when using the power cords provided together with the product and EIZO-specified signal cables. • Only use EIZO accessories products specified by EIZO with this product. Precautions for Use • Parts (such as the LCD panel and the fan) may deteriorate if used over extended periods of time.
Notice for this monitor room to a warm room. In that case, do not turn the product on. Instead wait until the dew condensation disappears, otherwise it may cause some damage to the product. To Use the Monitor for a Long Time Quality control •...
• Look at the screen from a proper distance and from a proper angle. Cybersecurity Warnings and Responsibilities • Firmware update should be performed through EIZO Corporation or its distributor. • If EIZO Corporation or its distributor instructs to update the firmware, update it immediately.
1.1.8 Space-saving design................17 1.1.9 Monitor operation from the mouse and keyboard ........18 Package Contents....................18 1.2.1 EIZO LCD Utility Disk................19 1.2.2 RadiCS LE ....................19 1.2.3 To use RadiCS LE .................. 19 Controls and Functions ..................20 1.3.1...
Page 14
CONTENTS Attaching RadiLight Focus (Task Light) .............. 29 Turning On the Power ..................29 Adjusting the Screen Height and Angle .............. 30 Attaching the Connector Cover ................31 Using RadiLight Area / RadiLight Focus ............. 32 3 No-Picture Problem....................33 4 Specifications ......................
Introduction | 1 1 Introduction Thank you very much for choosing an EIZO color LCD monitor. 1.1 Features 1.1.1 Free layout • This product is equipped with PbyP (Picture by Picture) and PinP (Picture in Picture) functions that can display up to three signals at the same time.
1 | Introduction Note • To display video signals, the connected device must support transmission of video signals (DisplayPort Alt Mode). • To use the charging function, the connected device must support device charging by using USB Power Delivery. • Only when the following USB cables are used, a maximum of 94 W of power can be supplied: –...
Introduction | 1 1.1.7 Equipped with a Lighting Function (RadiLight) RadiLight Area (Backlight) • RadiLight Area is a rear lighting function built into the monitor. It indirectly lights a room from the back of the monitor, allowing for efficient radiologic interpretations to be possible in dimly lit environments.
1.2 Package Contents Check that all of the following items are contained in the package. If any of these are missing or damaged, contact your dealer or local EIZO representative. Note • It is recommended that the box and packing materials be stored so that they can be used to move or transport this product.
Introduction | 1 1.2.1 EIZO LCD Utility Disk The CD-ROM contains the following items. Refer to "Readme.txt" on the disk for software startup procedures or file reference procedures. • Readme.txt file • RadiCS LE monitor quality control software (for Windows) • User’s Manual –...
1 | Introduction 1.3 Controls and Functions 1.3.1 Front Approx. 30° 1. Integrated Front Sensor This sensor is used to perform calibration and Grayscale Check. (Movable) 2. Illuminance Sensor This sensor measures environmental illumination. Environmental illumination measurement is performed using the RadiCS / RadiCS LE quality control software.
Introduction | 1 1.3.2 Back 1. RadiLight Area Rear lighting function built into the monitor. It indirectly lights a room (Backlight) from the back of the monitor. 2. Stand Adjusts the height and angle (tilt and swivel) of the monitor. 3. Main power switch Turns the main power on or off.
Page 22
1 | Introduction 12. USB-C connector To set up a daisy-chain connection, connect the cable to the USB-C (downstream) upstream connector of another monitor. In addition, you can connect a peripheral USB device (see "Using the Docking Station Function" in the Installation Manual). 13.
Installation / Connection | 2 2 Installation / Connection 2.1 Before installation Carefully read PRECAUTIONS [} 3] and always follow the instructions. If you place this product on a lacquer-coated desk, the color may adhere to the bottom of the stand due to the composition of the rubber. Check the desk surface before use. 2.1.1 Installation conditions When installing the monitor in a rack, ensure that there is adequate space around the sides, back and top of the monitor.
2 | Installation / Connection 2.2 Connecting Cables Attention • Check that the monitor, PC, and peripherals are powered off before connecting. • When replacing the current monitor with this monitor, see 4.2 Supported Resolutions [} 37] change the PC settings for resolution and vertical scan frequency to those that are available for this monitor, before connecting the PC.
Page 25
Installation / Connection | 2 In PbyP (DisplayPort 1 / DisplayPort 2) display Signal cable: PP300-V14 Signal cable: PP300-V14 Attention • To perform PbyP (DisplayPort 1 / DisplayPort 2) display, you need to configure "PbyP Settings" in the Setting menu. For details, refer to the Installation Manual (on the CD-ROM). •...
Page 26
2 | Installation / Connection In PbyP (One Cable PbyP) display Signal cable: PP300-V14 Signal cable: CC150SS81G-5A Attention • To perform PbyP (One Cable PbyP) display, connect to the DisplayPort 1 connector or the USB- C connector (Upstream: ). In addition, you need to configure the "PbyP Settings" setting in the Setting menu.
Page 27
Installation / Connection | 2 In PinP (Sub window) display Example: Using the HDMI connector Signal cable: HH300PR Signal cable: PP300-V14 Attention • To perform PinP (Sub window) display, you need to configure the "PinP Settings" setting in the Setting menu. For details, refer to the Installation Manual (on the CD-ROM). •...
Page 28
Signal cable: CC150SS81G-5A Signal cable: CP200 (optional, sold separately) Attention • Visit the EIZO web site for information about monitors and graphics boards that can be used for the daisy-chain connection: (www.eizoglobal.com) • To set up a daisy-chain connection, connect to the DisplayPort 1 connector or the USB-C connector (Upstream: ).
Installation / Connection | 2 2.3 Attaching RadiLight Focus (Task Light) Attach RadiLight Focus (task light) to the task light connector of the monitor. It can only be attached in a downward direction perpendicular to the connector. To remove it, pull it out while turning the connecting part with the monitor in the direction indicated by 1 in the illustration.
2 | Installation / Connection Attention • When connecting for the first time or changing the connection method, display settings such as resolution and display scale may not be appropriate. Check if the settings for the PC are properly configured. • For power saving purposes, it is recommended that the Power button be turned off. When not using the monitor, you can turn off the main power supply or disconnect the power plug so that the power is cut completely.
Installation / Connection | 2 2.6 Attaching the Connector Cover 1. Organize cables in the cable holder. 2. Attach the connector cover. Example: Attaching the connector cover (right) Attention • Make sure to attach it securely to ensure proper ventilation inside the monitor. Note •...
2 | Installation / Connection 2.7 Using RadiLight Area / RadiLight Focus 1. Make sure the monitor and computer are turned on. 2. Use the operation switches to turn RadiLight Area or RadiLight Focus on/off. Adjusts the brightness of RadiLight Area. RadiLight Focus On/Off RadiLight Area Brightness Down / Brightness Up / On/Off Attention...
• Turn off the main power switch on the back of the monitor, and then turn it on again. Power switch indicator blinks: Orange, Green • Connect using a signal cable specified by EIZO. Then turn off the main power switch on the back of the monitor, and then turn it on again a few minutes later.
Page 34
Manual of the graphics board for details. The message "DP Unsupported" appears on the screen • Check whether the connected cable is a signal cable recommended by EIZO. • Check whether the USB-C of the connected device supports video signal output (DisplayPort Alt Mode).
Specifications | 4 4 Specifications 4.1 List of Specifications 4.1.1 Type RX670 Anti-Glare RX670-AR Anti-Reflection 4.1.2 LCD Panel Type Color (IPS) Backlight Size 30.0" (76.2 cm) Resolution 3280 dots x 2048 lines Display Size (H x V) 645.5 mm x 403.0 mm Pixel Pitch (H x V) 0.197 mm x 0.197 mm Display Colors...
Sierra (10.12) or later Wired LAN IEEE802.3ab (1000BASE-T) IEEE802.3u (100BASE-TX) IEEE802.3 (10BASE-T) EIZO support will end when OS vendor support ends. 4.1.6 Power Input 100 – 240 VAC ±10 %, 50 / 60 Hz, 2.80 – 1.20 A Maximum Power Consumption...
Appendix Appendix Medical Standard • It shall be assured that the final system is in compliance to IEC60601-1 requirement. • Power supplied equipment can emit electromagnetic waves, that could influence, limit or result in malfunction of the monitor. Install the equipment in a controlled environment, where such effects are avoided.
WARNING • RadiForce RX670 should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the configuration in which it will be used.
Appendix WARNING • Be sure to use the cables attached to the product, or cables recommended by EIZO. Use of cables other than those recommended by EIZO for this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and improper operation.
Page 41
RadiForce RX670 has been tested at the following compliance levels (C) according to the testing requirements (T) for Professional healthcare facility environments and Home healthcare environments specified in IEC60601-1-2. The customer or the user of RadiForce RX670 should assure that it is used in such an environment. Immunity test...
Page 42
Compliance level Electromagnetic environment - Guidance Portable and mobile RF communications equipment should be used no closer to any part of RadiForce RX670, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Page 43
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which RadiForce RX670 is used exceeds the applicable RF compliance level above, RadiForce RX670 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating RadiForce RX670.
Page 44
(30 cm) between portable and mobile RF communications equipment (transmitters) and RadiForce RX670. RadiForce RX670 has been tested at the following compliance levels (C) for the required test levels (T) of immunity to the proximity electromagnetic fields in the following RF communication services.
Page 45
Appendix The customer or the user of RadiForce RX670 can suppress interference caused by proximity magnetic fields by maintaining a minimum distance (15 cm) between the RF transmitter and RadiForce RX670. RadiForce RX670 has been tested at the following compliance levels (C) for the required test levels (T) of proximity magnetic field immunity.
Note Use the attached specified cable below or EIZO signal cable with this monitor so as to keep interference within the limits of a Class B digital device. • AC Cord •...
Need help?
Do you have a question about the RadiForce RX670 and is the answer not in the manual?
Questions and answers