Download Print this page

Outer Panels / Fan Motor / Electrical Components - Daikin RC35PRV16 Service Manual

Advertisement

Outer Panels / Fan Motor / Electrical Components

1. Outer Panels / Fan Motor / Electrical Components
Warning
Step
1. Remove the outer panels.
1
Remove the screw, and
then the stop valve
cover.
2
Remove the 2 screws,
and then the top panel.
2
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Stop valve
cover
(R20986)
Hook
Hook
(R20987)
Top panel
(R16334)
Si011404EC
Points
The stop valve cover is
united with the shield plate.
When reassembling, make
sure to fit the 5 hooks.
Removal Procedure