Reading Mode; Trigger Mode; Continuous Mode - IMAGO K-60 Instruction Manual

Table of Contents

Advertisement

3 Reading mode

3.1 Trigger mode

In the trigger mode, when the trigger control interface of the reading module changes to the
trigger level, the reading module starts shooting and reading; within the limited time range of
"single reading time", if the trigger level is maintained, it will continue shoot and read until you
succeed. When the trigger level is cancelled, or the reading exceeds the single reading time limit,
the shooting and reading will be suspended. When the reading is successful, the reading module
will output the edited content through the communication interface. To start a new trigger
reading, the host needs to cancel the trigger level first, and then send the trigger level.

3.2 Continuous mode

Continuous mode refers to the working mode in which the reading module shoots, reads and
outputs information in a continuous cycle.In this mode, regardless of whether it is the same bar
code, the reading module will recognize and output.
In continuous mode, the trigger can be used to stop continuous reading or continue
continuous reading.In continuous reading, the trigger is withdrawn again, and the reading will be
suspended.When the reading state is suspended, the trigger is revoked and the reading
continues.This configuration may not be in effect while in continuous reading state.
* trigger mode
Continuous Mode