2 Wireless part setting 2.1 Bluetooth pairing setting code (1)R&B4.0 wireless scanning gun is compatible with 2.4g, bluetooth BLE4.0 communication, the engine and host through TTL/RS232 communication docking, the engine head communication mode needs to be set to serial communication (wireless setting), baud rate is 15200bps (bluetooth setting).
②When R&B scanner gun is connected to bluetooth device: scan the pairing code I and II for pairing: (after scanning the pairing code, open the bluetooth device for bluetooth search and connection) The pairing code I disconnect The pairing code II connect 2.2 Show and hide keyboard (for apple devices only) Show or hide the keyboard...
①Operation in stocktaking mode Upload all data Upload new data Show saved data Show upload data Clear all the data 2.4. Singlechip restore factory setup 2.5 Set upload data delay (valid when connecting to cell phone) No delay delayed...
2.6 Query software version Query scanner sofeware version Query the receiving end version number 2.7 Set the sleep time X=1yyy (xxx1000 is non-dormant, sleep time formula: yyy*10=z seconds) non-dormant 60 seconds 120 seconds 5 minutes 10 minutes 2.8 Set bluetooth broadcast time...
X=2yyy(Broadcast formula:yyy*5=z s) Note: the minimum broadcast time is 30 seconds 120s 2.9 USB KBW When the reading mode is connected to the host using the USB cable, the reading mode can be configured as a standard keyboard by scanning the USB KBW setting code.
2.12 Transmission speed selection Don't delay Delay 5 ms Delay 10 ms Delay 15 ms Delay 20 ms Delay 25 ms Delay 30 ms Delay 35 ms Delay 40 ms Delay 45 ms...
2.13 Multinational keyboard When the engine is recognized as a keyboard input device, some of the input characters vary from country to country, and different languages are required. The keyboard defaults to USA English. * USA Belgium Finland France Germany Italy Sweden Denmark...
Slovakia Slovenia Switzerland-French Switzerland-German 2.14 Output forced letter case conversion Keyboard alphabetic conversion. When you output a bar code with letter content, you can configure the output to be all uppercase or lowercase. For example, if the bar code is: ab123de, if "converted to uppercase"...
3 Reading mode 3.1 Trigger mode In the trigger mode, when the trigger control interface of the reading module changes to the trigger level, the reading module starts shooting and reading; within the limited time range of "single reading time", if the trigger level is maintained, it will continue shoot and read until you succeed.
3.3 Autosensing Mode Setting into the autosensing mode,the reader will immediately began to monitor the brightness of the surrounding environment, when the scene changes, the reader waits for the set of image stabilization time after the end of reading. After reading the successful output of information or single reading time-out, the reader will be some time interval (can be set) to re-enter the monitoring state.
4 Lighting and aiming 4.1 Lighting Lighting for shooting photography to provide auxiliary lighting, beam exposure to the reading target, to improve reading performance and adaptability to weak ambient light. The user can set it to one of the following depending on the application environment: Normal (default setting): The light is on when taking a picture, and off at other times.
5 Prompt output 5.1 Prompt tone volume *High volume Mid volume Low volume 5.2 All beeps In various scenarios, the reading module has the boot prompt sound, the successful reading prompt sound and the setting code prompt sound.This setting code can control all the prompts. Sound off *Sound on 5.3 Invoice mode...
5.4 Data Editing 5.4.1 Comprehensive settings For all "add" operations The "add" operation refers to: start character, code ID addition, custom prefix information addition, custom suffix information addition, and terminator addition. The following "Allow all information to add" and "Prohibit all information to add" have an effect on the above several functions at the same time.
5.4.4 Prefix and Code ID order selection When both the Code ID and Prefix fields are configured to require output, the order of the two fields can be selected through the following two setting codes, and the content order of the other fields will be output later。...
5.6 Code ID 5.6.1 add Code ID Users can use Code ID to identify different bar code types, and the Code ID corresponding to each bar code type can be modified freely. The CodeID of all barcodes is 1 character, and must be a letter, and cannot be set as a number, invisible character, or punctuation, etc.
Page 22
Modify Modify QR Code ID DM Code ID Modify Modify EAN13 Code ID EAN8 Code ID Modify UPCE0 Code ID Modify UPCE1 Code ID Modify UPCA Code ID Modify IATA25 Code ID Modify Code 39 Code ID Modify Code 93 Code ID Modify Interleaved 2 of 5 Code ID Modify Codabar Code ID Modify Industrial 25 Code ID...
Modify ISBN Code ID Modify ISSN Code ID Modify GS1 128 Code ID Modify AIM 128 Code ID Modify ISBT 128 Code ID Modify Micro PDF417 Code ID Modify Aztec Code ID 5.7 Suffix 5.7.1 Add a suffix The suffix is a character string that can be customized and modified by the user after decoding the information.
Example: Set the custom suffix to "CODE": 1. Check the character table to get the hexadecimal value corresponding to the 4 characters of "CODE": 43, 4F, 44, 45; 2. Read the "Enable Setting Code" (if it is already turned on, you can ignore it); 3.
Modify the terminator to be the letter 0x0D Example: 1. Read the "Enable Setting Code" (if it is already turned on, you can ignore it); 2. Read the "modify end character" setting code; 3. Read the data code "0", "D"; 4.
5.9.2 Data segment length modification Modify the length of the Start section Modify the length of the End section It is necessary to read the corresponding setting code and use it in combination with the data code. The length can be modified from 0-255. Modify the length of the Start segment to 0x02, example: 1.
6 Barcode symbol parameters 6.1 Global operations 6.1.1 Operations on all symbol types Reading the following setting codes will operate on all supported symbol types, allowing or prohibiting reading. After prohibiting reading all types, only setting codes are allowed to be read. Allow reading all types Prohibit reading all types 6.1.2 Operation on all one-dimensional bar code symbol types...
Inverse color code setting If this configuration is turned on, the recognition speed will be affected. Please turn it on in the scene you need to use. 6.2.1 Operate all reverse color codes Allow to read the reverse color code *Prohibit read the reverse color code 6.2.2 1D code reverse color setting Allows to read 1D reverse color code...
EAN-8 6.4.1 Restore default settings EAN8 ( Defaulted) 6.4.2 Enable/Disable EAN-8 *Enable EAN-8 Disable EAN-8 6.4.3 Output verification EAN-8 The barcode data is fixed to 8 bytes, of which the last byte is the checksum. *Output check No output check 6.4.4 Extension code After setting to "Read 2-digit extension code"...
6.5.5 EAN13 to ISBN Other configurations are the same as EAN13. Disable EAN13 to ISSN Enable EAN13 to ISSN 6.5.6 EAN13 to ISSN Other configurations are the same as EAN13. * Disable EAN13 to ISSN Enable EAN13 to ISSN UPCE0 6.6.1 Restore default settings UPCE0 ( Defaulted) 6.6.2 Enable /Disable UPC-E0...
6.7.4 Extension code After setting to "Read 2-digit extension code" or "Read 5-digit extension code", the reader module can read barcode symbols with extension codes, or barcode symbols without extension codes. After setting to "Do not read 2-digit extension code" or "Do not read 5-digit extension code", the extension code attached to the bar code symbol will not be read and output.
6.8.4 Output verification *Output check No output check 6.8.5 Output system characters *Output system characters No output system characters 6.8.6 Extension code After setting to "Read 2-digit extension code" or "Read 5-digit extension code", the reader module can read barcode symbols with extension codes, or barcode symbols without extension codes.
6.9.1 Enable /Disable InterLeaved25 *Enable InterLeaved25 Disable InterLeaved25 6.9.2 Set length limit *Set minimum length limit 00 Set minimum length limit 04 Set maximum length limit 32 *Set the maximum length limit to 255 Customize the minimum length Customize the maximum length 6.9.3 Check and output check Interleaved 2 of 5 barcodes do not require verification, and users can choose to use verification according to different applications.
USS check but not output check USS verification and output verification 6.10 Matrix 2 of 5 6.10.1 Restore default settings Restore Matrix 25 default settings 6.10.2 Enable/Disable Matrix 25 Enable Matrix 25 *Disable Matrix 25 6.10.3 Set length limit *Set minimum length limit 00 Set minimum length limit 04 Set maximum length limit 32 *Set the maximum length limit to 255...
Customized the minimum length Customized the maximum length 6.11.4 Check and output check *No check out Check but not output check Check but not output check 6.12 IATA 2 of 5 6.12.1 Restore default setting IATA 25 ( Defaulted) 6.12.2 Enable/ Disable IATA 25 Enable IATA 25 *Disable IATA 25...
6.12.3 Set length Limit *Set minimum length limit00 Set minimum length limit04 Set maximum length limit32 *Set minimum length limit255 Customized the minimum length Customized the maximum length 6.12.4 Check and output check *No check Check but not output check Check and output check 6.13 Code 39 6.13.1 Restore default setting...
6.13.2 Enable/Disable Code 39 *Enable Code 39 Disable Code 39 6.13.3 Enable/Disable Starting character and Ending character starting character and Ending starting character and Ending Enable *Disable character character 6.13.4 Enable/Disable Set Length Limit *Set minimum length limit00 Set minimum length limit04 Set maximum length limit32 *Set maximum length limit255 Customized minimum length...
6.13.5 Check and output check *No Check Check but not output check Check and output check 6.13.6 Disable/Enable Code32 *Disable Code32 Enable Code32 6.13.7 Full ASCII Support The encoding method of Code 39 can include the representation of all ASCII characters. By setting, the reading module can support bar codes containing the full ASCII character set.
Module 16check and output check Module 16Check but not output check 6.14.5 Enable/Disable Starting character and Ending character There is a character before and after the Codabar barcode data as the start character and the stop character. The start character and the stop character are one of the four characters "A", "B", "C", and "D".
Customized minimum length Customized maximum length 6.18 PDF 417 *Enable PDF 417 Disable PDF 417 6.19 QR Code *Enable QR Disable QR 6.20 Micro QR Enable Micro QR *Disable Micro QR 6.21 Data Matrix *Enable Data Matrix Disable Data Matrix...
7 Data Code 7.1 Data code 0~F Data code 0 Data code 1 Data code 2 Data code 3 Data code 4 Data code 5 Data code 6 Data code 7 Data code 8 Data code 9 Data code A Data code B Data code C Data code D...
7.2 Save or Cancel After reading the data code, it is necessary to read the save code to save the read data. In addition to resetting, if you make an error while reading the data code, you can also cancel reading the wrong data.
Appendix A: Default Settings Table Parameter name Default settings Remark Code setting Code function setting Enable Send out code setting info Do not send out Communication setting Keyboard Baud rate 9600 Check No check TTL-232 Data bit 8 bits Stop bit Stop bit 1 bit Hardware flow control...
Page 52
Lighting and aiming Lighting mode Normal Aiming mode Normal Prompt output Power on prompt Output Parameter name Default settings Remark Notification Allow Reading successful Prompt type Type 3 Prompt Prompt volume High Setting bit reading prompt Allow Succeed reading LED notification Open Sending out notification Do not send out...
Page 53
Reading Enable Output check character Output 2-bit extension code Disable 5-bit extension code Disable EAN13 to ISBN Disable EAN13 to ISSN Disable Parameter name Default settings Remark UPC-E0 Reading Enable Output check character Output Output system character Output UPC-E1 Reading Enable Output check character Output...
Page 54
Max length Min length IATA25 Reading Check Output check character Max length Parameter name Default settings Remark Min length Code 39 Reading Enable Check Output check character Output starting character and ending character Full ASCII support Convert to Code 32 Max length Min length Codabar...
Page 55
PDF417 Reading Enable Reading Enable Micro QR Reading Data Matrix Reading Enable Micro PDF417 Reading Parameter name Default settings Remark Aztec Reading Inverse color code...