Recommended Spare Parts; Specifications - Ecolab Chameleon PLUS BW3 Service Manual

Hide thumbs Also See for Chameleon PLUS BW3:
Table of Contents

Advertisement

7. Recommended spare parts

The recommended spare parts are marked with * in the spare part manual.

8. Specifications

Technical Data
Water
Unit.
Max. Outlet pressure.
Consumption during rinsing. 1)
Consumption during foaming.
Min. supply pressure.
Max. supply pressure.
Min. water supply.
Max. water temp.
Pipe dimension inlet Ø
Pipe dimension outlet Ø
Electricity
Supply voltage
Frequency
Hz
Motor load (kW)
kW
Nominal current
A
Fuse
A
L1, L2, L3, PE
mm2
General
Sound level ISO 11202
dB
Dimensions
mm
Weight (kg)
kg
All specifications are based on 5 bar supply pressure
Note:
* Pump pressure 20 bar + inlet pressure max. 25 bar
** Pump pressure 20 bar + inlet pressure max. 22 bar
1) 1 user per 30l/min.
14
Advanced*
Proff.**
3 (4 kW)
3 (4 kW)
bar
25
25
L/min
90
90
L/min
30
30
bar
2
2
bar
8
8
L/min
100
100
°C
70
70
inch
1.1/4"
1.1/4"
inch
1.1/4"
1.1/4"
V
4
4
10.6
10,6
16
16
2.5
2.5
Below 70
Below 70
1070 x 550 x 375
785 x 550 x 375
85
60
Booster/Main station.
4 (5.5 kW)
7 (10 kW)**
25
22
120
210
40
80
2
2
8
8
135
265
70
70
1.1/4"
2"
1.1/4"
2"
3/PE 400 V ±10%
50/60 Hz 48 0%...62 +0%
5.5
10
Installation to EN 60204-1
14.2
27
20
35
2.5
6
Below 70
Below 70
1074 x 557 x 382
1074 x 557 x 382
75
75
8 (11 kW)*
25
240
80
2
8
265
70
2"
2"
10
27
35
6
Below 70
990x535x364
80