battery remains discharged, the process continues
until recharging the battery becomes impossible.
If the battery does become run down be sure to
recharge it as soon as possible. Over charging the
battery can be just as detrimental to its life as running
it down too far
CAUTION
!
• NEVER use an open flame in the battery
storage area.
• Avoid striking sparks near the battery.
• A battery will explode if a flame or spark
ignites the free hydrogen given off during
charging.
• ALWAYS disconnect the battery before
doing any work or maintenance on the
electrical system.
• NEVER turn off the battery switches or
disconnect the battery cables while the
engines are running.

Main DC Breakers

The Main DC breaker resets are located on the
forward wall of the console interior (Figure 4.2.1).
In the event that a main DC breaker trips, determine
and correct the problem prior to resetting the breaker.
DC Main Breakers
Fig. 4.2.1
1
2
1
MAIN DC BREAKER ............................ 25 AMP
2
ELECTRONIC MAIN BREAKER ......... 25 AMP
3
BILGE BREAKER ................................... 5 AMP
4
ACCESSORY BREAKER ....................... 5 AMP
4-2
Section 4 • Electrical System
3
4
CAUTION
!
NEVER reset a breaker without first determining
and correcting the cause of the trip. Should
a circuit repeatedly trip, have a qualified
electrician determine and correct the cause.

Component Breakers

Component breakers are located on the helm switch
panel. If a component breaker trips, determine and
correct the problem before resetting the breaker.
Should a circuit breaker trip repeatedly, have a
qualified electrician determine and correct the cause
of the trip.
Component Circuit Breakers
Fig. 4.2.2
SPEEDOMETER
TACHOMETER
1
HORN BREAKER ................................10 AMP
2
NAV/ANC BREAKER .............................3 AMP
3
COURTESY LIGHT BREAKER ............5 AMP
4
BILGE PUMP BREAKER ......................6 AMP
5
ACCESSORY BREAKER ......................3 AMP
WARNING
!
Use of higher amperage breakers is a fire
hazard.
Use breakers having the same amperage rating
as the original or as specified.
R
HORN
BILGE
NAV/ANC
CRTSY
ACC
PUMP
LIGHT