Pid Control Parameters - Savch S3100E Series User Manual

Table of Contents

Advertisement

09 Accessibility parameters
Parame
Parameter function
ter
Arbitrary arrival current 1
09-38
09-39
Arbitrary arrival current 1 width
Arbitrary arrival current 2
09-40
Arbitrary arrival current 2 width
09-41
Timing function selection
09-42
Timed running time selection
09-43
Timed running time
09-44
Lower limit of AVI1 input voltage
09-45
protection value
Upper limit of AVI1 input voltage
09-46
protection value
Module temperature reached
09-47
Cooling fan control
09-48
Wake frequency
09-49
Wake delay time
09-50
Sleep frequency
09-51
Sleep delay time
09-52
Arrival time setting for this run
09-53

10 PID Control parameters

Parame
Parameter function
ter
PID given source
10-00
PID data given
10-01
 indicates that the parameters can be set during operation
Setting range
0.0%~300.0%( motor rated current )
0.0%~300.0%( motor rated current )
0.0%~300.0%( motor rated current )
0.0%~300.0%( motor rated current )
0:Invalid
1:Valid
0:09-44 setting
1:AVI1
2:AVI2/ACI
3:Reserved
Analog input range corresponds to 09-44
0.0Min~6500.0Min
0.00V~09-46
09-45~11.00V
0℃~100℃
0:Fans run during operation
1:The fan keeps running
Sleep frequency (09-51)~ max
frequency (00-03)
0.0s~6500.0s
0.00Hz~ Wake frequency (09-49)
0.0s~6500.0s
0.0Min~6500.0Min
 indicates that the parameters can be set during operation
Setting range
0:10-01 setting
1:AVI1
2:AVI2/ACI
3:Reserved
4:PULSE setting(MI5)
5: Communication setting
6: Multi-step speed command given
0.0%~100.0%
50
Factory
setting
100.0%
0.0%
100.0%
0.0%
0
0
0.0Min
3.10V
6.80V
75℃
0
0.00Hz
0.0s
0.00Hz
0.0s
0.0Min
Factory
setting
0
50.0%