Model GP8060 / GP8060-1000
Flow .......................................................... 90 GPM ................ (340 LPM)
Discharge Pressure .................................. 2465 PSI .............. (170 bar)
Power Consumption ................................. 142 BHP ............... 106 kW
Maximum Speed ....................................... 580 RPM ............... 580 RPM
Inlet Pressure ............................................ 29 PSI .................. (2.0 bar)
Plunger Diameter ...................................... 2.36" ...................... 60 mm
Plunger Stroke .......................................... 2.83" ...................... 72 mm
Crankshaft Diameter ................................. 2.76" ...................... 70 mm
Key Width ................................................. 0.55" ...................... 14 mm
Crankshaft Mounting ................................................................ Either side
Shaft Rotation .......................................................................... Top of pulley towards manifold
Temperature of Pumped Fluids ................. Up to 86
Inlet Ports ................................................................................. (2) 3" BSP
Discharge Ports ....................................................................... (2) 1-1/4" BSP
Weight ....................................................... 749 lbs. ................. (340 kg)
Crankcase Oil Capacity ............................ 3.3 Gal. ................ (12.5 liters)
Valve Casing Material (GP8060) ............................................. Nickle plated Spheroidal Cast Iron
Valve Casing Material (GP8060-1000) .................................... Aluminum Bronze
NPSHR ..................................................... 26.2 ft.-head .......... 8.0 mWs
*higher water temperatures possible with separate crankcase cooling system; contact Giant.
Consult the factory for special requirements that must be met if the pump
is to operate beyond one or more of the limits specified above.
GP8060/GP8060-1000
HORSEPOWER REQUIREMENTS
RPM GPM 500 PSI 1000 PSI 2000 PSI 2500 PSI
300 46.0
15.9
400 61.4
21.2
500 76.7
26.5
580 89.0
30.7
SPECIAL NOTE:
The theoretical gallons per revolution (gal/
rev) is 0.153. To find specific outputs at vari-
ous RPM, use the formula:
GPM = 0.153 x RPM
Specifications
U.S.
31.7
63.5
79.3
42.3
84.7
105.9
52.9
105.8
132.2
61.4
122.8
153.5
4
(Metric)
F ........... (30
C)*
o
o
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the pump. Gas
engine power outputs must be
approximately twice the pump
power requirements shown above.
We recommend a 1.15
service factor be specified when
selecting an electric motor as the
power source. To compute spe-
cific pump horsepower require-
ments, use the following formula:
GPM X PSI
1450
= HP