3.2 Industrial PoE++ Injector Upper Panel
The upper panel of the IPOE-171 series has one terminal block
connector where there are two DC power inputs.
3.3 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of the IPOE-
171 series is used for two DC redundant power inputs. Please follow
the steps below to insert the power wire.
Step 1: Insert Positive/Negative DC power wires into Contacts 1 and 2
for POWER 1, or 5 and 6 for POWER 2.
10
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
V2+
PWR1
Alarm
PWR2
Figure 3: IPOE-171-60W upper panel.
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
V2+
PWR1
Alarm
PWR2
Figure 4: IPOE-171-95W upper panel.
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
V2+
PWR1
Alarm
PWR2
Figure 5: Power input pins.
DC Input:
48-54V
, 2A max.
DC Input:
12-54V
, 6A max.
DC Input:
12-54V
, 6A max.