Page 1
Installation and Operation Manual HT-3000 (DB07300 model) US Environmental Protection Agency phase II certified wood stove compliant with 2020 cord wood standard Safety tested according to ULC S627, UL 1482 and UL 737 standards by an accredited laboratory. MOBILE HOME CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN LOCAL AREA.
Page 3
It is also highly recommended to register the warranty online at https://www.drolet.ca/en/warranty/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit. Installation and Operation Manual - HT-3000 Page 3...
6.3 Glass Door ........................22 6.4 Door ..........................23 6.5 Exhaust System ........................24 PART B - INSTALLATION ......................26 7. Safety Information and Standards ..................26 7.1 Mobile Home ........................26 7.2 Regulations Covering Stove Installation ................26 Page 4 Installation and Operation Manual - HT-3000...
Page 5
Appendix 7: Air Tubes and Baffle Installation ................46 Appendix 8: Mobile Home Installation ..................48 Appendix 9: Exploded Diagram and Parts List ................ 49 DROLET Limited Lifetime Warranty ................... 52 Dealer: Installer: Phone Number: Serial Number: Installation and Operation Manual - HT-3000 Page 5...
This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov/ Installation and Operation Manual - HT-3000 Page 7...
Optimum overall efficiency at a specific burn rate (LHV). This appliance is officially tested and certified by an independent agency. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 Carbon monoxide. Page 8 Installation and Operation Manual - HT-3000...
CAN/CSA- Z240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17. Installation and Operation Manual - HT-3000 Page 9...
5 more minutes, then close the primary air control halfway. After another 5 minutes, close the primary air control completely for the low burn rate and leave it halfway for the medium burn rate. Installation and Operation Manual - HT-3000 Page 11...
Although the stove may be able to heat the main living areas of the house to an adequate temperature, it is strongly recommended to also have a conventional oil, gas or electric heating system to provide backup heating. Page 12 Installation and Operation Manual - HT-3000...
Hardwoods are denser than softwoods. Homeowners with access to both hardwood and softwood use both types for different purposes. Installation and Operation Manual - HT-3000 Page 13...
Continually burning green or unseasoned wood produces more creosote and involves lack of heat and dirty glass door. Firewood with a moisture content between 15% and 20% will allow the stove to produce its highest possible efficiency. Page 14 Installation and Operation Manual - HT-3000...
It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual. Before using the stove, install the coil handles located in the user manual kit. Installation and Operation Manual - HT-3000 Page 15...
It is also possible to install a heat sensor, sold separately. The heat sensor must also be installed at the back of the stove. See «Appendix 4: Optional Thermodisc Installation». When the blower is on (position between HI and LO), the heat sensor will make the blower start automatically Page 16 Installation and Operation Manual - HT-3000...
Place three or four small, split, dry logs in the firebox. Arrange the kindling wood on the logs in two layers at right angles and place a dozen finely split kindling on the second row. Installation and Operation Manual - HT-3000 Page 17...
This is especially true if the chimney is on the outside wall of the house. If the door must be opened while the fire is flaming, fully open air control for a few minutes then open the door slowly. Page 18 Installation and Operation Manual - HT-3000...
No other waste should be placed in this container. NEVER STORE ASHES INDOORS OR IN A NON-METALLIC CONTAINER OR ON A WOODEN DECK. CENDRES ASHES Installation and Operation Manual - HT-3000 Page 19...
Place the biggest pieces at the back of the firebox and place the rest of the pieces compactly. A densely built fire like this will produce the longest combustion this stove is capable of. Page 20 Installation and Operation Manual - HT-3000...
Page 21
Open the door slightly and move the log with a poker. Turn it over and create a passage for the air below, making a trench with the coal bed. Add small pieces of wood to restart the combustion. Installation and Operation Manual - HT-3000 Page 21...
The glass gasket should be self-adhesive. Always replace the gasket with a genuine one. Do not clean the glass when the stove is hot. Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken. Page 22 Installation and Operation Manual - HT-3000...
The test must be performed all around the door. If the paper slips out easily anywhere, either adjust the door or replace the gasket. Installation and Operation Manual - HT-3000 Page 23...
Smouldering, smoky fires can quickly cause a thick layer of creosote to form. When the stove is operated properly, the exhaust from the chimney is mostly clear and creosote builds up more slowly. Page 24 Installation and Operation Manual - HT-3000...
Page 25
Do not use the appliance again until the stove and its chimney have been inspected by a qualified chimney sweep or a fire department inspector. Installation and Operation Manual - HT-3000 Page 25...
It is recommended to note the stove serial number on page 5 of this manual since it will be needed to precisely identify the version of the appliance in the event replacement parts or technical assistance is required. Page 26 Installation and Operation Manual - HT-3000...
For a safe way to reduce clearances refer to section «8.3 Reducing Clearances Safely» 48" 36" 122 cm 92 cm 84" (L) 213 cm Figure 10: Clearances - Top Figure 9: Clearances - Side Figure 11: Clearances - Corner Installation and Operation Manual - HT-3000 Page 27...
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall pipe connector can be used. Page 28 Installation and Operation Manual - HT-3000...
Page 29
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe connector to be used as close as 6» from combustible materials must be used. Only in this case, the same clearances as a certified double wall pipe connector can be used. Installation and Operation Manual - HT-3000 Page 29...
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above mentioned. Page 30 Installation and Operation Manual - HT-3000...
The floor protection at the back of the stove is limited to the stove’s required clearance if such clearance is smaller than 8 inches (203 mm). Only required under the horizontal section (Ho) of the connector. Must exceed each side of the connector by at least 2 inches (51 mm). «Figure 9: Clearances - Side» Installation and Operation Manual - HT-3000 Page 31...
Page 32
Mounting hardware must not be located closer than 8" (200 mm) from the vertical centre line of the appliance. G) Edge clearance for ceiling shields to side and back walls: 3" (75 mm). Shield extension beyond each side of the appliance: 18" (450 mm). Page 32 Installation and Operation Manual - HT-3000...
Page 33
Brick, with a minimum of 24 gauge (0.61 mm) sheet metal backing, spaced out at least 1" (25 mm)* by non-combustible spacers 12" (305 mm) * In Canada this space can be ⅞" (21 mm). Installation and Operation Manual - HT-3000 Page 33...
Only components intended for the brand and model of chimney should be used. Never fabricate or substitute parts from other chimney brands. The chimney must be a type suitable for solid fuel. Page 34 Installation and Operation Manual - HT-3000...
Page 35
Do not downsize the flue to less than 6" (150 mm) unless the venting system is straight and exceeds 25' (7,6 m) in height. When passing through a combustible wall, the use of an insulated listed thimble is required. Installation and Operation Manual - HT-3000 Page 35...
A reddish glow on the unit and on the chimney components indicates overheating. Excessive temperatures can cause a chimney fire. Figure 13: Good System Design Figure 14: Inferior System Design Page 36 Installation and Operation Manual - HT-3000...
In some windy conditions, negative pressure near hood may draw hot exhaust gases from the stove to outdoors. Check the outdoor air duct for soot deposits when the full system is cleaned and inspected at least once each year. Installation and Operation Manual - HT-3000 Page 37...
• Minimum clearance from combustible material: 18" (450 mm). The minimum clearance may be reduced by 50%, to 9" (225 mm) if proper heat shield is installed either on the pipe or on the combustible surface. Page 38 Installation and Operation Manual - HT-3000...
Page 39
Where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment. • The chimney connector must be clean and in good condition. Installation and Operation Manual - HT-3000 Page 39...
(HVAC type, must meet ULC S110 or UL 181 class 0 or class 1) (B), sold separately. Refer to air intake kit installation instructions for more details. Page 40 Installation and Operation Manual - HT-3000...
Lift the fire screen upwards and push the bottom part towards the stove then let the fire screen rest on the bottom of the door opening. Warning: Never leave the stove unattended while in use with the fire screen. Installation and Operation Manual - HT-3000 Page 41...
Ensure that the blower’s power cord is not in contact with any surface of the stove to prevent electrical shock or fire damage. Do not run the power cord beneath the stove. Page 42 Installation and Operation Manual - HT-3000...
Screw the thermodisc (C) with the screws (D) provided on the back of the stove. The electrical cord of the thermodisc should not touch any surface of the stove to avoid electric shock or fire. Do not run the power cord under the stove. Installation and Operation Manual - HT-3000 Page 43...
APPENDIx 5: REMOVING THE DECORATIVE PANELS To remove the decorative panels (B), remove the screws (A) and push forward on the panel to unhook it from the support (C). Page 44 Installation and Operation Manual - HT-3000...
Put the baffle in place. Repeat steps 1 and 2 for the three other tubes. To remove the tubes use the above steps in reverse order. Page 46 Installation and Operation Manual - HT-3000...
Page 47
Note that secondary air tubes (B) can be replaced without removing the baffle board (A) and that all tubes are identical. Installation and Operation Manual - HT-3000 Page 47...
Shall your unit or a component be defective, contact immediately your DROLET dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling: •...
Page 53
Installation and Operation Manual - HT-3000 Page 53...
Page 54
Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec), Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002 of information contained in any document obtained from https://www.drolet.ca/en/ unauthorized sources. tech@sbi-international.com...
Need help?
Do you have a question about the HT-3000 and is the answer not in the manual?
Questions and answers