QMS 1060 User Manual page 98

Print system reference
Table of Contents

Advertisement

Sets the rate at which data is transmitted (bits per second) by the host
over the serial interface.
Menu
Administration/Communications/Serial/Baud Rate
Choices
300, 600, 1200, 2400, 4800, 9600, 19200, 38400
Default
9600
Notes
Set this option to match the baud rate used by your host.
Baud rates of 19200 and 38400 require RTS/CTS
protocol hardware flow control (Administration/
Communications/Serial/Hdwe Flow Ctl menu).
If you select a baud rate of 2400 or below, the
Administration/Communications/Timeouts/Emul
Timeout value should be increased to the following
values:
Baud Rate
2400
1200
600
300
*
Sets the check bit used to identify data transmission errors.
Menu
Administration/Communications/Serial/Parity
Choices
Even, Ignore Parity, None, Odd
Default
None
Notes
The printer's parity setting must match that of the host or
application.
A baud rate of 2400 works with an Emulation Timeout
value of 5, but there is no margin for delays between
characters.
Emulation Timeout (seconds)
10*
20
40
80

Advertisement

Table of Contents
loading

Table of Contents