Outside Fresh Air Connection; Exhaust And Fresh Air Intake Locations - HAMPTON BAY Greenfire GCi60-2 Technical Manual

Cast iron pellet insert
Hide thumbs Also See for Greenfire GCi60-2:
Table of Contents

Advertisement

o
f
-a
c
utSide
reSh
ir
This Heater must have adequate air for proper combustion in the room that it is installed.
A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may
result in improper combustion as well as the unit smoking
during power failures.
The inlet to the intake must be below and a minimum of 12"
(30cm) away from the unit exhaust outlet.
Outside fresh air is mandatory when installing this
unit in airtight homes and mobile homes.
When connecting to an outside fresh air source, do not use
plastic or combustible pipe. A 3" minimum (76 mm) ID
(inside diameter) steel, aluminum or copper pipe or ducting
should be used. The inlet must have a screen installed. It is
recommended, when you are installing a fresh air system, to
keep the number of bends in the pipe to a minimum.
e
a
f
a
xhauSt
nd
reSh
5.120
3.000
4.952
Figure 8: GCI60 Inlet and Outlet Location.
Hampton GCi60-2 Cast Pellet Insert Technical Manual
Installation
:
onnection
i
l
:
ir
ntake
ocationS
9.624
Outside
3" ID
(76 mm)
Figure 7: Outside Air Connection.
This unit uses a 4" exhaust vent.
4.000
EXHAUST:
Base of unit to center of flue
16
" (413 mm)
/
1
4
Center of unit to center of flue
9
/
" (245 mm)
5
8
FRESH AIR INTAKE.
Base of unit to center of intake
5
" (130 mm)
/
1
8
Center of unit to center of intake
5" (128 mm)
16.373
Wall
Optional
Elbow
13